NTC HC10B Скачать руководство пользователя страница 2

 

Program 1: Settings for Monday to Friday, and settings for Saturday and Sunday. 

Time zone 

Mon - Fri 

Temperature 

Sat - Sun 

Temperature 

Wake 

  5:00 

–   8:30 

22 

o

7:00 

–  23:00 

22 

o

Leave 

  8:30 

– 15:00 

18 

o

 

 

Home 

15:00 

– 22:00 

22 

o

 

 

Sleep 

22:00 

–   5:00 

18 

o

7:00 

–  23:00 

18 

o

 
Program 2: Settings for All Weekdays. 

Time zone 

All days 

Temperature 

Wake 

  7:00 

– 23:00 

22 

o

Sleep 

23:00 

–   7:00 

18 

o

 
Program 3: Settings for Each Day of the Week separately. 

Time zone 

Mon, Tue….. 

Temperature 

    Wake 

  5:00 

–   8:30 

22 

o

Leave 

  8:30 

– 15:00 

18 

o

Home 

15:00 

– 22:00 

22 

o

Sleep 

22:00 

–   5:00 

18 

o

 
D)  Floor and room sensors 

Two sensors, a floor sensor and a room sensor provide HC10B with feedback on the current temperature in the room or the floor. 
The feedback from the sensors is necessary to maintain the desired temperature in the room. 
The sensors can be used separately or together. 

 

Floor sensor (FL) 

 

Room sensor (RO) 

 

Combined use of room and floor sensor (CO). 
In (CO) setting, the room sensor controls the room temperature, while the floor temperature*) is simultaneously monitored by 
the floor sensor. The HC10B monitor is set to a desired minimum temperature and a desired maximum temperature. The 
factory settings are 27 and 15

o

C respectively. (CO) should be selected when heating is installed under a timber floor. 

*) Temperature measured by floor sensor. 

 

 
E)  HC10B backup battery 

HC10B is equipped with a battery ensuring around 100 hours' backup. If the power has failed and the backup battery is active, the 
display will show OFF. If Heat Control has been without power for more than around 100 hours, the backup battery will be empty. 
When the power returns again, HC10B will start up with the factory settings Quickstart and 21 degrees. 
Any changes made to the programs will be lost. 
 

Programming the HC10B. 

1)  Important! Start here 

before you activate any night and day setback program

 

Set the day of the week and the clock. 

  Press [P] and confirm with [OK] 

  Hours will flash 

 

Use [▼] or [▲] to set the hours. 

  Press [

  Minutes will flash 

 

Use [▼] or [▲] to set the minutes.  

  Press [

  Day will flash 

 

Use [▼] or [▲] to choose present day. i.e. Mon = Monday, Tue = Tuesday 

  Confirm by pressing [OK]. 

 

2)  Setting the functions and altering the programs 

2.1) Set HC10B to floor sensor 

  Press [

] for approx. 4 secs. 

  (FL), (RO) or (CO) will flash on the display. 

 

Press one of the arrow keys [▼] or [▲] until (FL) shows on the display. 

  Confirm by pressing [OK]. 

 

The underfloor heating will now be controlled by the signal from the floor sensor. The display will show the temperature the floor will 
reach. 
Note: The temperature shown on the display will typically be lower than the room temperature. 
 
2.2) Setting HC10B to room sensor 
The use of room sensor is recommended if there is no floor sensor in the floor.  

  Press [

] for approx. 4 secs. 

  (FL), (RO) or (CO) will flash on the display. 

  Press one of the arrow 

keys [▼] or [▲] until (RO) shows on the display. 

  Confirm by pressing [OK]. 

 
The underfloor heating will now be controlled by the signal from the room sensor. The display will show the temperature the air in 
the room will reach. Room sensor can be calibrated if desired (see point 13). 
 