  Plug the charger cord into an electrical outlet        

(120 VAC). 

  Let the battery charger charge the battery until the 

green LED is lit. 

See Battery Charger section for more details. 

Preparing the Solution Tank:

 

  Make sure the filter basket is in place to keep debris 

from getting into the solution tank. 

  Fill solution tank to the desired level. 

  Add chemical following the directions provided on the 

chemical bottle label. 

  The solution tank will hold 4 gallons (15 liters). 

 

ALWAYS

 follow the chemical manufacturer’s 

instructions printed on their product’s label. 

Installing the Spraying Wand Assembly: 

  Connect the wand assembly to the shut-off valve. 

          

 

  Connect the spray nozzle to the wand assembly. 

 

  Tighten all connections to prevent leaks. 

Operating the Machine 

Plug the charged battery into the machine.    

WARNING:

 only use the 24V Lithium ion battery 

provided or replacement purchased from NSS 
Enterprises, Inc.  Use of any other battery can result in 
serious harm or injury to the operator and series 
damage to the machine. 

 

Priming the pump: 

  Remove the top cap to the solution tank. 

  Turn on the power switch. 

  Spray solution back into the solution tank to prime the 

pump. 

  Close the shut-off.  Pump should stop running. 

  Replace the top cap to the solution tank. 

  Begin spraying. 

MACHINE MAINTENANCE

 

Routine maintenance is critical to ensure proper 
machine operation and cleaning performance. Perform 
all maintenance procedures as follows. 

Always turn OFF all machine switches before 
performing any maintenance. 

Daily Maintenance 

Battery Charging 

  Recharge the battery after every use. 

  Battery charge should take 3.5 to 4 hours from fully 

depleted. 

  When not in use, battery should be left connected to 

the battery charger. 

Solution Tank

 

  Empty and clean the solution tank after use. 

  Empty and rinse out the filter basket as required. 

Weekly Maintenance (20 hours) 

  Verify all daily maintenance has been performed. 

  Flush solution tank and spraying wand assembly with 

water.  Check for leaks in the connections. 

  Repair or replace any worn or damaged components 

as needed. 

  Inspect spray pattern at the spray nozzle.  Clean out if 

necessary. 

 

Machine Storage 

Always remove the battery from the machine and put on 
charge prior to storing the machine. 
 

  The machine should be stored out of direct sunlight in 

a cool, dry place. 

  If exposed to freezing temperatures, make sure to 

drain all liquid from the solution tank, pump, hose, 
and spraying wand assembly. 

  Lock the shut-off valve in the “open” position. 

 

Содержание Opti-Mist BB

Страница 1: ...OPERATION MANUAL Opti Mist BB Chemical Sprayer...

Страница 2: ...tennis shoes or non slip shoes Leather soled shoes will become extremely slippery when wet ALWAYS empty the tank after use NEVER allow this machine to freeze NEVER expose the machine to rain snow or e...

Страница 3: ...his machine which is specifically designed to the charge its 24V Lithium Ion battery NEVER splash or immerse the battery with water or any other liquid NEVER store the or use the machine and battery w...

Страница 4: ...should be replaced It is recommended to recharge the battery as soon as possible after each use or battery life may be greatly diminished For longest battery life do not discharge the battery fully Fo...

Страница 5: ...tank and begins to curve The harness belt buckle is adjustable to fit the size of the operator Spraying Wand Assembly The spraying wand assembly includes a shut off valve wand assembly and spray nozz...

Страница 6: ...ion tank to prime the pump Close the shut off Pump should stop running Replace the top cap to the solution tank Begin spraying MACHINE MAINTENANCE Routine maintenance is critical to ensure proper mach...

Страница 7: ...To maximize the life of the battery it is designed to shutoff abruptly when the charge is depleted Place the battery on charge and allow the charge to complete Shut off leaks The connection s is loose...

Страница 8: ...acement 4994231 Repair Parts Kit Shut off 4994241 Wand Assembly Replacement 4994251 Repair Parts Kit O rings ALWAYS USE GENUINE NSS REPLACEMENT PARTS OPTI MIST BB Rev Orig 07 20 Rev A 07 20 9094944 NS...

Отзывы: