PROBLEM
CAUSE
SOLUTION
Pad Does Not Turn
Low Battery Charge.
Recharge Batteries.
Loose Battery Cable.
Tighten & Clamp battery Cables.
Circuit Breaker Has Tripped.
Reduce Pad Pressure/Change Pad
Reset Breaker.
Worn Motor Carbon Brushes.
Change Carbon Brushes.
Pad Load Adjustment Knob.
Adjust Knob Until Motor Will
Out Of Adjustment.
Turn On.
Microswitch Not Engaged.
Adjust Mounting Bracket.
Machine Pushes Hard
Worn Wheel Or Caster.
Grease Wheels Or Replace.
Uneven Floor Buffing
Worn Pad.
Change pad.
Motor out of Alignment.
Call NSS Service Center For Repair.
Machine Vibrates
Pad Is Torn Or Not Centered.
Center pad.
Change Pad. Use Correct Pad.
Check Pad Driver For Damage &
Replace If Necessary.
Circuit Breaker Trips
Pad Pressure Too Heavy.
Reduce Pad Pressure. Run Machine
In Green Area of AMP Meter.
Spray Buffing.
Do Not Spray With Charger
2300BP/2500BP.
Pad Rubbing On Flexiwall
Realign Pad On Driver Or Replace
Shield
with new pad. Check Pad size.
Short Running Time
Dead Cell In Battery
Test Batteries And Replace.
On Battery Charge
Excessive Pad Pressure.
Reduce Pad Pressure.
Incorrect Pad.
Use NSS Pads Or Recommended
Equivalent.
Battery Charger Does
Connection Not Made Between
Check Anderson Connectors For
Not Turn On
Battery Charger And Machine
Proper Contact On Both Charger
And Machine.
Improper Charger Sequence.
Read Instructions On Battery
Charger Or In Instruction Manual.
WIRING DIAGRAM