NSS Enterprises CHAMP 3529 RB Скачать руководство пользователя страница 8

 

 

TRIO+:   Scrubber System Diagnostic Codes 

Scrubber System Faults External to TRIO+ 

Code

 

Fault Description

 

Corrective Action

 

0810  Throttle fault-1.0 

For all Throttle Diagnostic Codes: 

0811  Throttle max wiper difference error. 

1- Check the throttle wiring for shorts or opens. Repair or replace as 
necessary. 

0812  Throttle max pull down difference 

error. 

2- If Diagnostic Code is not cleared, then replace throttle 
(Potentiometer). 

0813  Throttle max pull safe difference error.          "        "        "        " 
0814  Throttle reference error. 

        "        "        "        " 

0815  Throttle lo reference error. 

        "        "        "        " 

0816  Throttle hi reference iso error. 

        "        "        "        " 

0817  Throttle lo reference iso error. 

        "        "        "        " 

0818  Throttle error both have readings. 

        "        "        "        " 

1310  Excessive current trip. 

High Voltage - Battery Voltage exceeds Controller Parameters. 

1311  Soft aux 1 over current occurred. 

Brush Lift Actuator exceeded current limit. 
Check limit switch settings, wiring, or replace. 

1312  Soft aux 2 over current occurred. 

Squeegee Lift Actuator exceeded current limit. 
Check limit switch settings, wiring, or replace. 

1313  Soft aux 3 over current occurred. 

Solution Solenoid exceeded current limit. Check wiring, or replace. 

1314  Soft aux 4 over current occurred. 

Overhead Light or Head Light exceeded current limit.  
Check wiring (diodes), or replace device. 

1318  Soft brake light over current occurred.  Horn circuit exceeded current limit. 

Check wiring (diodes) or replace device. 

131C  Soft alarm over current occurred. 

Beeper circuit exceeded current limit. Check wiring or replace 
device. 

1321  Aux 1 over current 2 occurred. 

Brush Lift Actuator exceeded current limit. 
Check limit switch settings, wiring, or replace. 

1322  Aux 2 over current 2 occurred. 

Vac Lift Actuator exceeded current limit. 
Check limit switch settings, wiring, or replace. 

1411  Error aux 1 positive shorted - low. 

Check Brush Lift Actuator and wiring. 
Repair or replace as necessary. 

1412  Error aux 1 negative shorted - low. 

Check Brush Lift Actuator and wiring. 
Repair or replace as necessary. 

1413  Error aux 2 positive shorted - low. 

Check Squeegee Lift Actuator and wiring. 
Repair or replace as necessary. 

1414  Error aux 2 negative shorted - low. 

Check Squeegee Lift Actuator and wiring. 
Repair or replace as necessary. 

1501  Brake fault 2. 

Check Brake circuit wiring and brake. 
Repair or replace as necessary. 

1507  Brake over current error. 

Check Brake circuit wiring and brake. 
Repair or replace as necessary. 

1600  High battery error. 

Battery is overcharged or damaged. Replace battery. 

1D02  Front-end spec change trip. 

Drive parameters have been reprogrammed.  
Cycle power with key switch.  

1E03  Inhibit activated. 

Fix whatever condition is causing Inhibit signal. 

1E04  Inhibit activated 2.  

Fix whatever condition is causing Inhibit signal. 

1E06  Inhibit input out of range. 

Invalid Inhibit signal. Check wiring and device. 
Repair or replace as necessary. 

Содержание CHAMP 3529 RB

Страница 1: ... this machine when the battery charger is plugged in NEVER operate this machine with the side skirt removed NEVER allow this machine to be used as a toy Close attention is necessary when used by or near children ALWAYS wear clean tennis shoes or non slip shoes Leather soled shoes will be extremely slippery when wet ALWAYS keep face fingers hair or any other body part or loose clothing away from an...

Страница 2: ...th proper voltage rating For lead acid batteries only does not apply to gel cell or maintenance free batteries ALWAYS check to ensure the battery water level covers the battery plates before charging ALWAYS check water level after charging and add water if necessary to bring level to the bottom of the fill hole NEVER overfill batteries as battery and machine damage may result ALWAYS wipe any acid ...

Страница 3: ... brushes to light pressure Middle is off raising brushes Down is on lowering brushes to heavy pressure Brushes only come on when machine is moving in forward or reverse LCD Display Screen brightly lit to work in all lighting situations Traction Speed Switch 3 Positions Down is high speed Center is medium speed Up is low speed Push Button Toggles between display screens Defaults to screen 1 when tu...

Страница 4: ...ISPLAY SCREENS There are many symbols that can be displayed on the LCD Therefore the LCD Push Button can be used to toggle between pre defined screens see Control Panel for Details Screen 2 Screen 3 Screen 1 ...

Страница 5: ...iver The pad must be centered on the driver to prevent wobbling or bouncing Install and secure the pad holding cup to the pad driver Turn the pad driver over so that the pad faces the floor Raise the brush motor into the transport position center position of switch Align the lugs of the pad driver with the notches of the drive casting Turn the pad driver to lock onto the drive casting Close the lo...

Страница 6: ...ng constant current stage The current bar graph will indicate the current to the battery as the charger moves through its charge profile The length of charge time will vary by how large and how depleted the battery pack is 4 When the yellow 80 LED is lit the charger has completed the bulk stage of the charge and the battery is at approximately 80 of charge The charging could be terminated at this ...

Страница 7: ...est LED indicating that Algorithm 1 is selected the second lowest LED indicates that Algorithm 2 is selected etc For all algorithm s the algorithm number is also indicated on the 80 LED by the number of blinks separated by a pause Note algorithms 7 9 are indicated only with the 80 LED indication no bar graph indication is given Check or change the charging algorithm a Disconnect the positive conne...

Страница 8: ...cuit exceeded current limit Check wiring diodes or replace device 131C Soft alarm over current occurred Beeper circuit exceeded current limit Check wiring or replace device 1321 Aux 1 over current 2 occurred Brush Lift Actuator exceeded current limit Check limit switch settings wiring or replace 1322 Aux 2 over current 2 occurred Vac Lift Actuator exceeded current limit Check limit switch settings...

Страница 9: ...r locked rotor conditions debris caught in brushes gear box locked up etc Repair or Replace as necessary 7604 Soft brush inhibit Check Brush Motor for excessive amp draw when starting Repair or Replace as necessary 7605 Brush startup over current detection Check Brush Motor for excessive amp draw Check for locked rotor conditions debris caught in brushes gear box locked up etc Repair or Replace as...

Страница 10: ...105 3608 1 Turn Off Key switch and disconnect batteries 0204 1B20 3200 3609 2 Wait 1 minute 0705 1B21 3201 360a 3 Reconnect Batteries and turn On Key switch 0706 2102 3210 360b 4 If Diagnostic Code is not cleared then replace TRIO 0A01 2103 3211 360c 0B02 2D01 3212 360d 0B0B 3100 3213 360e 1704 3101 3214 7501 1705 3102 3601 1706 3103 3602 ...

Страница 11: ...arge batteries Batteries Do Not Seem To Run Long Enough Battery terminals are dirty damaged Clean terminals and connectors replace damaged cables Electrolyte level is too low Add water and charge Batteries are not fully charged Charge batteries for 8 hours Charger is damaged Have an authorized serviceman repair Battery is defective Check cell voltage while discharging Wrong size battery Replace wi...

Страница 12: ...NE 419 531 2121 FAX 419 531 3761 NSS Enterprises Inc European Distribution Centre Unit II Pinfold Trading Estate 55 Nottingham Road STAPLEFORD NOTTINGHAM NG9 8AD ENGLAND U K PHONE 44 0115 939 1568 FAX 44 0115 949 0615 CHAMP 3529 Operation Manual 9097634 Orig 10 04 ...

Отзывы: