TROUBLE SHOOTING
PROBLEM CAUSE
SOLUTION
No Solution Flow.
The solution valve is closed.
Open the solution valve.
Water solenoid valve not open.
Charge the battery.
Obstruction in the solution hose.
Remove the obstruction.
Solution valve or cable damaged.
Repair / replace the valve cable.
Solution tank is empty.
Fill the tank.
Solution valve is dirty.
Clean the solution valve.
Damaged seat and washer in valve.
Replace valve.
Squeegee is up.
Lower squeegee.
Will Not Pick Up Any Water
From The Floor.
Vac motor switch is “off”.
Turn vac motor switch “on”.
Recovery tank is full.
Empty tank.
Vacuum shut-off float is stuck.
Remove obstruction.
Hole in squeegee hose.
Replace hose.
Vac motor is not running.
Have an authorized serviceman repair.
Drain plug not in tight.
Tighten drain plug.
Porthole cover is missing.
Replace porthole cover.
Squeegee blade is worn / damaged.
Reverse / replace squeegee blade.
Obstruction / damage in the squeegee,
squeegee hose or standpipe.
Remove obstruction / repair damage.
Tops of batteries are dirty / wet.
Clean / dry, charge batteries.
Batteries Do Not Seem To
Run Long Enough.
Battery terminals are dirty / damaged.
Clean terminals, and connectors,
replace damaged cables.
Electrolyte level is too low.
Add water and charge.
Batteries are not fully charged.
Charge batteries for 8 hours.
Charger is damaged.
Have an authorized serviceman repair.
Battery is defective.
Check cell voltage while discharging.
Wrong size battery.
Replace with larger batteries.
Batteries have memory — recharging
prematurely will result in a loss of
battery capacity.
Don’t recharge batteries until
“Battery Re-charger” indicator is
displayed.
Battery tray full.
Drain battery tray.
Cleaning Is Not Even.
Brush / pads are worn.
Replace.
Damage to brush assembly or solution
valve.
Have an authorized serviceman repair.
Motor is not running.
Check circuit breakers. Reset if
necessary, replace carbon brushes,
repair wiring, replace switch.
Not enough or uneven water.
Check solution hose for blockage.
Machine Does Not Run.
Check circuit breaker.
Reset circuit breaker. Check battery
connections.
Code on control panel.
Contact authorized repair service center.
NOTE:
If problems remain after taking the above steps, contact your local authorized service station for further
evaluation and repair.