NSS Enterprises CHAMP 3529 RB Скачать руководство пользователя страница 7

 

Maintenance Instructions 

1.  For flooded lead-acid batteries, regularly check 

water levels of each battery cell after charging and 
add water as required to level specified by battery 
manufacturer. Follow the safety instructions 
recommended by the battery manufacturer. 

2.  Make sure charger connections to battery 

terminals are tight and clean. 

3.  Do not expose charger to oil or to direct heavy 

water spraying when cleaning machine. 

DC Battery Connection Procedure

1.  The Green wire outputs a battery voltage when the 

charger is not plugged in to AC to provide an 
Interlock function. 

2.  Securely fasten the Black / White ring terminal from 

the battery charger to the negative terminal ("-", 
"NEG", NEGATIVE") of the battery pack. 

3.  Securely fasten the Red wire ring terminal from the 

battery charger to the positive ("+", "POS", 
"POSITIVE") of the battery pack. 

4.  Select Charge Algorithm if battery type is other than 

factory default. 

Check / Change Charging Algorithm: 

The charger comes pre-loaded with nine algorithms 
for Lead Acid batteries as detailed in Table 1. Each 
time AC power is applied with the battery pack NOT 
connected, the charger enters an algorithm 
select/display mode for approximately 11 seconds - 
this is the only time the algorithm can be changed. In 
this mode, the present algorithm is displayed on the 
LED bar graph or 80% LED as shown in Table 1. 
If the algorithm # is from one to six, it will be 
displayed on the bar graph with the lowest LED 
indicating that Algorithm 1 is selected; the second 
lowest LED indicates that Algorithm 2 is selected, etc. 
For all algorithm #’s, the algorithm number is also 
indicated on the 80% LED by the number of blinks 
separated by a pause. ** 

Note- algorithms 7-9 are 

indicated only with the 80% LED indication - no bar 
graph indication is given. 

Check or change the charging algorithm

a.  Disconnect the positive connector from battery 

pack. Apply AC power and after an up/down flash 
of the LEDs, the algorithm # will display for 11 
seconds. 

b.  To change algorithm, touch connector during the 

11-second display period to the battery pack’s 
positive terminal for 3 seconds and then remove- 
the algorithm # will advance after 3 seconds. 
Repeat until desired algorithm # is displayed. A 30 
second timeout is extended for every increment. 
Incrementing beyond algorithm 9 moves back to 
algorithm 1.  After desired algorithm is displayed, 
touch the charger connector to the battery positive 
until the output relay is heard to click (~10 
seconds) algorithm is now in permanent memory. 

c.  Remove AC power from the charger and 

reconnect the charger positive connector to the 
battery pack. It is highly recommended to check a 
newly changed algorithm by repeating the above 
steps a) and c). 

 
 

Delta-Q Battery Charger - Battery Types

 

NSS Part 

Number 

Crown Part 

Number 

Battery

 Volts

 

S

yst

em V

o

lt

s

 

Amp Hour

 

 Recomme

nd

ed 

Algorithm 

4491061 1-1470 12  36 210

3390361 

1-1435 

24 & 36

225

# 1 

2392111 1-1427 12  24 115

6393651 1-1428 12  24 145

2392731** 1-12145  12 

24  100

6491931** 

1-1437 

24 & 36

180

# 6 

2691501 1-1450  6  36 325

7691401 1-1460  6  36 395

Table 1. 

** Note: Gell Battery 

Содержание CHAMP 3529 RB

Страница 1: ... this machine when the battery charger is plugged in NEVER operate this machine with the side skirt removed NEVER allow this machine to be used as a toy Close attention is necessary when used by or near children ALWAYS wear clean tennis shoes or non slip shoes Leather soled shoes will be extremely slippery when wet ALWAYS keep face fingers hair or any other body part or loose clothing away from an...

Страница 2: ...th proper voltage rating For lead acid batteries only does not apply to gel cell or maintenance free batteries ALWAYS check to ensure the battery water level covers the battery plates before charging ALWAYS check water level after charging and add water if necessary to bring level to the bottom of the fill hole NEVER overfill batteries as battery and machine damage may result ALWAYS wipe any acid ...

Страница 3: ... brushes to light pressure Middle is off raising brushes Down is on lowering brushes to heavy pressure Brushes only come on when machine is moving in forward or reverse LCD Display Screen brightly lit to work in all lighting situations Traction Speed Switch 3 Positions Down is high speed Center is medium speed Up is low speed Push Button Toggles between display screens Defaults to screen 1 when tu...

Страница 4: ...ISPLAY SCREENS There are many symbols that can be displayed on the LCD Therefore the LCD Push Button can be used to toggle between pre defined screens see Control Panel for Details Screen 2 Screen 3 Screen 1 ...

Страница 5: ...iver The pad must be centered on the driver to prevent wobbling or bouncing Install and secure the pad holding cup to the pad driver Turn the pad driver over so that the pad faces the floor Raise the brush motor into the transport position center position of switch Align the lugs of the pad driver with the notches of the drive casting Turn the pad driver to lock onto the drive casting Close the lo...

Страница 6: ...ng constant current stage The current bar graph will indicate the current to the battery as the charger moves through its charge profile The length of charge time will vary by how large and how depleted the battery pack is 4 When the yellow 80 LED is lit the charger has completed the bulk stage of the charge and the battery is at approximately 80 of charge The charging could be terminated at this ...

Страница 7: ...est LED indicating that Algorithm 1 is selected the second lowest LED indicates that Algorithm 2 is selected etc For all algorithm s the algorithm number is also indicated on the 80 LED by the number of blinks separated by a pause Note algorithms 7 9 are indicated only with the 80 LED indication no bar graph indication is given Check or change the charging algorithm a Disconnect the positive conne...

Страница 8: ...cuit exceeded current limit Check wiring diodes or replace device 131C Soft alarm over current occurred Beeper circuit exceeded current limit Check wiring or replace device 1321 Aux 1 over current 2 occurred Brush Lift Actuator exceeded current limit Check limit switch settings wiring or replace 1322 Aux 2 over current 2 occurred Vac Lift Actuator exceeded current limit Check limit switch settings...

Страница 9: ...r locked rotor conditions debris caught in brushes gear box locked up etc Repair or Replace as necessary 7604 Soft brush inhibit Check Brush Motor for excessive amp draw when starting Repair or Replace as necessary 7605 Brush startup over current detection Check Brush Motor for excessive amp draw Check for locked rotor conditions debris caught in brushes gear box locked up etc Repair or Replace as...

Страница 10: ...105 3608 1 Turn Off Key switch and disconnect batteries 0204 1B20 3200 3609 2 Wait 1 minute 0705 1B21 3201 360a 3 Reconnect Batteries and turn On Key switch 0706 2102 3210 360b 4 If Diagnostic Code is not cleared then replace TRIO 0A01 2103 3211 360c 0B02 2D01 3212 360d 0B0B 3100 3213 360e 1704 3101 3214 7501 1705 3102 3601 1706 3103 3602 ...

Страница 11: ...arge batteries Batteries Do Not Seem To Run Long Enough Battery terminals are dirty damaged Clean terminals and connectors replace damaged cables Electrolyte level is too low Add water and charge Batteries are not fully charged Charge batteries for 8 hours Charger is damaged Have an authorized serviceman repair Battery is defective Check cell voltage while discharging Wrong size battery Replace wi...

Страница 12: ...NE 419 531 2121 FAX 419 531 3761 NSS Enterprises Inc European Distribution Centre Unit II Pinfold Trading Estate 55 Nottingham Road STAPLEFORD NOTTINGHAM NG9 8AD ENGLAND U K PHONE 44 0115 939 1568 FAX 44 0115 949 0615 CHAMP 3529 Operation Manual 9097634 Orig 10 04 ...