5
2.2 Technical Data
IHN010
Voltage (± 9%):
1 ~ 110 – 240V / 50 – 60Hz*
Recommended circuit protection
10�5A circuit breaker (240V)
6�5A circuit breaker (110 – 115V)
Power consumption (maximum)
1�5kVA
Temperature control
20 – 180°C, in steps of 1°C
68 – 356°F, in steps of 2°F
Temperature probe
K-type thermocouple with magnetic bracket
Power range
20 – 100%, in steps of 20%
Time mode
0 – 10 minutes, in steps of 0�1 minutes
Operating modes
Automatic temperature or time mode
Demagnetisation, automatic
Residual magnetism < 2A/cm
Overall dimensions
340 x 250 x 64mm (over cone 121mm)
Weight
3�5kg
Workpiece:
Inner diameter
Width
External diameter
20mm and above
Up to 60mm
Up to 160mm
Workpiece maximum weight
Up to 10kg
Workpiece materials
Ferritic metals (magnetic)
Maximum heating temperature
< 180°C / 356°F
Authorisations, inspections
CE
* Each bearing heater family has several voltage options� Please refer to the type plate on the heater body to determine the actual operating voltage�