6
Console Configuration
Rear Panel
Dipswitch
The 8 Dipswitches on the rear panel serve special functions as follows:
Factory default is all switches off (up):
#1
MEMORY LOCK:
OFF (up) = Unlocked
ON (down) = Locked
#2
MICROPLEX MODE:
OFF (up) = Normal
ON (down) = Special
#3
CONFIGURE TAP PAD:
OFF (up) = Tap Sync
ON (down) = Manual step chase
#4
CONFIGURE LOCK:
OFF (up) = Unlocked
ON (down) = Locked
#5
PATTERN 1-8 ADD MODE:
OFF (up) = Normal
ON (down) = Always ADD mode
#6
RESERVED:
#7
RESERVED:
#8
RESERVED:
Memory Lock
The entire memory of the TLC 16 can be physically locked to prevent accidental changes to
the programmed patterns or scenes. This is highly recommended whenever the console is
not expected to be reprogrammed for a period of time.
If programming is attempted on a locked console, the Program LED will not light upon
tapping the Program pad.
TO LOCK MEMORY:
Place Dipswitch #1 in the ON (down) position.
TO UNLOCK MEMORY:
Place Dipswitch #1 in the OFF (up) position.