NSE EL-P Series Скачать руководство пользователя страница 26

22

Recommended separation distances between portable and mobile

 RF communications equipment and the EQUIPMENT or SYSTEM – 

for ME EQUIPMENT or ME SYSTEM that are not LIFE-SUPPORTING

The Medical LED Headlight is intended for use in an electromagnetic environment in which 

radiated RF disturbances are controlled. The customer or the user of The Medical LED 

Headlight can help prevent electromagnetic interference by maintaining a minimum distance 

between portable and mobile RF communications equipment (transmitters) and The Medical 

LED Headlight as recommended below, according to the maximum output power of the 

communications equipment.

For transmitters rated at a maximum output power not listed above, the recommended 

separation distance d in meters (m) can be estimated using the equation applicable to the 

frequency of the transmitter, where P is the maximum output power rating of the transmitter 

in watts (W) according to the transmitter manufacturer.

NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range 

applies.

NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is 

affected by absorption and reflection from structures, objects and people.

Recommended separation distances between portable and mobile RF communications 

equipment and The Medical LED Headlight Equipment.

0.01

0.1

1

10

100

0.117

0.369

1.167

3.690

11.67

150 kHz to 80 MHz
     d = 1.167  

0.117

0.369

1.167

3.690

11.67

0.233

0.738

2.333

7.377

23.33

P

80 MHz to 800 MHz
     d = 1.167  

P

800 MHz to 2,5 GHz
     d = 2.333  

P

Separation distance according to frequency of transmitter m

Rated maximum 

output power of 

transmitter W

Содержание EL-P Series

Страница 1: ...MEDICAL LED HEADLIGHT User Manual A 3...

Страница 2: ...d When first time open the package please check the describing spare parts are complete and in good condition If any spare part is incomplete or damaged please contact with your supplier Medical LED h...

Страница 3: ...ety Information 2 3 Safety Precaution 3 Structure and Component 3 1 Product Structure 3 2 Control Panel 4 Operation 4 1 Install Battery 4 2 Wear Product 4 3 Turn On LED Power 4 4 Adjust LED Light Dire...

Страница 4: ...15 16 16 17 17 19 5 2 Maintenance 5 3 Electronic Waste Disposal 5 4 Environment Safety and Disposal 6 After sales service Appendix ATechnical Parameters Appendix BEMC Declaration...

Страница 5: ...r different series The LED lamp connection method between A type and B type is different which can be referred to Figure 2 1 2 Intended Use This product is intended to provide professional lighting fo...

Страница 6: ...hich leads to fully adjustable light beam direction This structure makes operation more simple and convenient and it can maintain good performance after lots of adjustments Circuit System The low powe...

Страница 7: ...The symbol indicating separate collection for electrical and electronic equipment Class II equipment On ac adapter To identify equipment meeting the safety requirements specified for Class II equipme...

Страница 8: ...oducts or the accessories If product failure or abnormal should immediately stop using it and contact the supplier or manufacturer 4 2 2 Safety Information 1 Power Supply 2 Protection against electric...

Страница 9: ...hods in acceptable surroundings 2 Modification of this equipment is not permitted 3 Structure and Component 3 1 Product Structure 5 Figure 1 Medical LED Headlight Structure Rechargeable Battery LED Ho...

Страница 10: ...is non coaxial with LED housing C Rotation shaft connector The connector is diverse between different series product which can be referred to Figure 2 Please check the product to get more details The...

Страница 11: ...H L 3 2 Control Panel 7 Figure 3 Control Panel for EL Q series AC Adaptor Hole LED On Off Button Charging Indicator Brightness adjustment Switch Battery Socket with a battery in figure...

Страница 12: ...en cap between the fingers and pull it out with a little strength 2 Install a new one Take out a new cap and pinch it into the installation place Figure 4 Control Panel for EL P S T series LED On Off...

Страница 13: ...cking box then put it in battery socket besides control panel finally push it inward until it is firmly in place See Figure as below shown NOTE Using the battery designated by the manufacturer NSE 9 F...

Страница 14: ...buckle NOTE Notice product direction should make the letters NSE stand 4 3 Turn On LED Power Press the LED On Off button on the control panel for 2 seconds turn on off LED power The position LED On O...

Страница 15: ...red to Table 3 CAUTION 1 The product may be damaged if LED housing is adjusted overly 2 Caution the rising temperature of LED housing when the device was used for a long time 11 Table 3 Adjust Lamp Ir...

Страница 16: ...operation method can be referred to Table 4 NOTE Power consumption rises with the increase of brightness level Usually 3rd brightness level or below is recommended to achieve longer working time CAUT...

Страница 17: ...before battery replacement and installation 2 Make sure the AC adapter is disconnected with power supply before you need install or remove the battery from recharging socket of EL P S T series CAUTIO...

Страница 18: ...ease disconnect with power supply and unplug the charger NOTE Turn off the LED lamp during the recharging process is recommended for batter recharging effect Battery Indicator LED lamp blinking There...

Страница 19: ...essories 5 Maintenance 5 1 Product Cleaning Product Surface Cleaning Except for LED lamp Clean the product surface with a cloth slightly dampened with a mild solution of detergent Disinfect the produc...

Страница 20: ...ons and send it to the specialized recycling place CAUTION Please keep the battery away from the fire source so as to avoid explosion 5 4 Environment Safety and Disposal When this product reaches its...

Страница 21: ...ow Consumable parts such as battery Damage caused by using non NSE accessories Damage caused by accident abuse misuse fire earthquake or other external caused Damage caused by disassembling the compon...

Страница 22: ...45cm 35mm 35cm 55mm 40cm 18mm 2mm 3 000k 6 700k 100 000h 385 mm 645mm 100 240V 50 60Hz 0 3A 1 200mAh 3 7V or 2 000mAh 3 7V 18 500Lux Q40 20cm 25 000Lux Q40 20cm 40 000Lux 20cm 50 000Lux 20cm Beam Diam...

Страница 23: ...low and are not likely to cause any interference in nearby electronic equipment The Medical LED Headlight is not suitable for interconnection The Medical LED Headlight is suitable for use in all esta...

Страница 24: ...or the user of The Medical LED Headlight should assure that it is used in such an environment Floors should be wood concrete or ceramic tile If floor are covered with synthetic material the relative h...

Страница 25: ...facture s declaration electromagnetic immunity for ME EQUIPMENT and ME SYSTEMS that are not LIFE SUPPORTING The Medical LED Headlight is intended for use in the electromagnetic environment specified b...

Страница 26: ...d separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W accordin...

Страница 27: ...Shanghai International Holding Corp GmbH Europe Eiffestrasse 80 20537 Hamburg Germany Rm 202 2 No 5 Tianfeng Rd Science City Development District 510530 Guangzhou PEOPLE S REPUBLIC OF CHINA EC REP...

Отзывы: