background image

3

Maintain the power of NSD Swim: 

Please be advised that the NSD Swim is required to recharge 

every 90 days if it is used less frequent. It should be recharged every day when NSD Swim is used 

frequently. 

Activate connection: 

First, turn on the Bluetooth through the Settings in your phone. Pull the rings at 

the two ends of NSD Swim with a force larger than 2 lbs and hold the force for 3 seconds. Now NSD 

Swim and the NSD Swimmer App in your smart phone should be automatically connected.

LED Indicator:

 

Flashing red light: Low power warning 

 

Constant red light: Charging

 

Flashing green light: Connecting stand-by

 

Constant green light: Connected

 

Red light turns off: Charging finished

DURING USE

Gear Up: 

1.Tie the two cords at the two ends of the NSD Swim device, the short cord is connected between

   NSD Swim and somewhere by the edge of the pool on a stable fixed item while the long cord is 

   connected between NSD Swim and the swimmer's floating belt. There is no direction positioning 

   the two ends of   NSD Swim. However, NSD Swim should NOT be put into water.

(Figure 2)

21*29.7cm

Содержание Swim SW-01

Страница 1: ...User Guide Learn More Electrical specifications 5V 1A Lithium battery 3 7V 450mAh Frequency 2402MHz 2480MHz Power 1 5dBm FCC ID 2AK45 NSD SW01 www NSDSwimmer com 21 29 7cm...

Страница 2: ...NSD Swim and the NSD Swimmer App are specifically designed for use in resistance swim training only NSD Swim and its accessories do not prevent drowning NSD Swim and its accessories are not floating...

Страница 3: ...remely tired after a training session stop and take a rest as you may be doing too much Stay hydrated during all training sessions At the end of each exercise slowly reduce the intensity to cool down...

Страница 4: ...your smart phone should be automatically connected LED Indicator Flashing red light Low power warning Constant red light Charging Flashing green light Connecting stand by Constant green light Connect...

Страница 5: ...the swimmers stomach 5 Open the NSD Swimmer App Figure 4 Figure 5 Figure 3 2 Tie one end of the cord to a stable fixed item near the edge of the pool as shown in figure 3 3 Tie the other end of the co...

Страница 6: ...splay settings Under My Info input Gender Height and Weight you may update it later Once you are finished entering your information you may start to use NSD Swim 6 Pull the cord or swim for 3 seconds...

Страница 7: ...Freestyle Breaststroke Backstroke or Butterfly 3 Start to swim 4 The App will display your real time performance according to your swim pulling force and patterns detected by NSD Swim 5 Calories char...

Страница 8: ...will display and update all matrix regarding your performance 6 In Training mode when you are finished training the green bar on the screen will move forward to the right end of the screen 7 When NSD...

Страница 9: ...ection will display historical best performance and the green section will display current performance 5 Once you start to swim under Historical best performance VS Current performance you will see a...

Страница 10: ...is less than historical record then your progress will be highlighted in red as shown in figure 16 below 7 There is an actual difference between the yellow and red bars as circled in figures 15 and 16...

Страница 11: ...alysis tab to enter Analysis mode as shown in Figure 17 2 You will find detailed statistics under History 3 If there is more than one record stored you may select records to compare and analyze the de...

Страница 12: ...ccuracy 1 Open Setting go to Calibration as shown in Figure 18 2 Tap Let s Calibrate 3 Input your gender height and weight as shown in figure 19 and then tap Next 4 Select swimming style to calibrate...

Страница 13: ...Precise Precise calibration needs to sample the time you spend on swimming in 25 meters Please gear up first Once you are ready press Begin Calibration and swim 6 On this screen as show in figure 22...

Страница 14: ...rference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the F...

Отзывы: