background image

www.nationalrailwaysupply.com 
1-800-357-3572 

39262A 

 

 

 

Figure 4.1 

Figure 4.2 

 

 

 

 

Rack Mounting 

The  charger  can  be  mounted  to  a 
standard 

Electronic 

Industries 

Association 

(EIA)  19”  (483mm)  rack 

system  using  the  fasteners  provided  by 
the  rack  manufacturer.    The  horizontal 
spacing  of  the  vertical  rows  of  holes  is 
specified 

by 

EIA-310 

at 

18-

5/16” 

(18.312)(465.1mm).    The  mounting 
flanges  are  configured  for  an  EIA  19” 
(483mm)  rack  for  a  forward  mounting 
arrangement  (note:  the  width  from  the 
outer edge fo one mounting flange to the 
outer  edge  of  the  other  mounting  flange 
is  19-

15/16”).    Fasteners  to  match  the 

thread of the rack should be used in all 7 
rack mounting horizontal slots on each of 
the  2  mounting  flanges  (14  rack 
mounting  slots  total)  to  maximize  the 
mounting integrity.  The fasteners should 
be  torqued  to  22  inch-pounds.    The 
dimensions  and  pattern  of  the  mounting 
flange  rack  mounting  slots  is  shown  in 
figures 4.2 and 4.3 

 

Figure 4.3 

 

Содержание ELC-24/30-D

Страница 1: ...al which may cause burns Do not get in eyes on skin or clothing If the gelled or liquid content of the batteries contacts the skin or clothing wash the area thoroughly with water In the case of contact with the eyes flush immediately with clean water for 15 minutes and obtain medical attention e Connect or disconnect the battery plug only when the charger output is off to prevent arcing or burning...

Страница 2: ...is not being used or the temperature probe is working improperly Temperature compensation uses a temperature reference of 77 F 25 C a voltage reference of 2 23 volts the voltage of a standard gel cell battery at 77 F and a compensation value of 3 0 mV per F or 5 4 mV per C The equivalent equation for the compensated voltage is Vcomp V k t 77 F Where V is the voltage of the battery at 77 F t is the...

Страница 3: ...g flanges are configured for an EIA 19 483mm rack for a forward mounting arrangement note the width from the outer edge fo one mounting flange to the outer edge of the other mounting flange is 19 15 16 Fasteners to match the thread of the rack should be used in all 7 rack mounting horizontal slots on each of the 2 mounting flanges 14 rack mounting slots total to maximize the mounting integrity The...

Страница 4: ... CAPACITOR 7 TEMPERATURE PROBE The external temperature probe is an optional way of extending battery life by using temperature compensation One end of the temperature probe cable has a three pin plug which plugs into a receptacle labeled TEMP PROBE on the front of the charger The other end of the cable has the temperature sensor sealed either in a terminal or small metal box WARNING IT IS IMPORTA...

Страница 5: ...cessary e Check the polarity between DC output and the battery and make sure their connections are tight f Remove the small cover on the front of the charger and make sure all of the binding posts nuts are tight g If the steps above do not solve the problem contact your local NRS service agent at 1 800 357 3572 11 CHARGER SPECIFICATIONS AC INPUT VOLTAGE 115 VAC 108 128 or 230 VAC 216 256 AC INPUT ...

Страница 6: ...SSEMBLY 15029S 2 FUSE 12 AMP 38888S 1 CIRCUIT BREAKER ASSEMBLY 31457S 1 AC SWITCH ASSEMBLY 27319S 1 AMMETER 50 AMP 14197S 4 BUSHING 1 29741S 1 TEMPERATURE TRANSDUCER 10 W TERMINAL 29742S 1 TEMPERATURE TRANSDUCER 30 W TERMINAL 14742S 1 HEATSINK ASSEMBLY W SCR 9 WIRE 15194S 1 HEATSINK ASSEMBLY W SCR 21 WIRE 23074S 1 SCR ASSEMBLY 50 AMP 21 WIRE 23073S 1 SCR ASSEMBLY 50 AMP 9 WIRE 15032S 2 OUTPUT CAPA...

Страница 7: ...www nationalrailwaysupply com 1 800 357 3572 7 39262A 13 WIRING DIAGRAM ...