background image

Issue: 02
Part Number: 31507884
Date: 2019-01-08

ESS-240V12-9AhBPVBA03 Modular 
Battery Pack
Quick Guide

1

Copyright © Huawei Technologies Co., Ltd. 2019. All rights reserved.

DC port 1

DC port 2

Name

Model

Function

Net Weight

Dimensions (H x W x D)

Battery 
pack

ESS-240V12-
9AhBPVBA03

Consists of five battery 
modules

84.1 kg

Battery pack: 130 mm x 
430 mm x 695 mm 
(including the front panel)

Battery 
module

ESS-48V12-
9AhBMVBA01

Each battery module consists 
of four 12 V/9 Ah lead-acid 
batteries.

14 kg

Battery module: 118.4 
mm x 70.4 mm x 657 mm 
(excluding the handle) 

Empty 
battery 
module

ESS-48V12-
9AhBMNBA

An empty battery module can 
house four 12 V/9 Ah or 12 V/7 
Ah lead-acid batteries.

2.5 kg

1. Batteries of the five battery modules in a battery pack must have the same capacity. 7 Ah and 

9 Ah batteries cannot be mixed together.

2. DC port 1 and DC port 2 of a battery pack are 6-pin PP45 terminals. One port connects to the 

UPS or the previous battery pack, and the other port connects to the next battery pack. DC port 
1 and DC port 2 have been connected in parallel inside. Do not connect them in series.

1

Product Overview

Battery 

module

Wiring terminals for battery packs 
and battery modules

Battery 

module 

wiring 

terminal 

(connects 

to a 

battery 

pack)

2

Installing Battery Modules

Use insulated tools, and wear insulation gloves and protective clothing.

Содержание ESS-240V12-9AhBPVBA03

Страница 1: ...dule ESS 48V12 9AhBMNBA An empty battery module can house four 12 V 9 Ah or 12 V 7 Ah lead acid batteries 2 5 kg 1 Batteries of the five battery modules in a battery pack must have the same capacity 7 Ah and 9 Ah batteries cannot be mixed together 2 DC port 1 and DC port 2 of a battery pack are 6 pin PP45 terminals One port connects to the UPS or the previous battery pack and the other port connec...

Страница 2: ...e battery pack and the long backup time model can connect to a maximum of 13 battery packs Battery packs cannot be shared in a parallel system Each of the positive and negative battery strings of the 15 kVA 20 kVA long backup time model needs to connect at least one battery pack If battery packs are not shared in a single UPS or a parallel system each of the positive and negative battery strings c...

Страница 3: ...e following figure shows how to connect cables when there are 13 battery packs Battery pack 1 ports Battery pack 2 ports UPS battery port Battery pack 13 ports Battery packs cannot be shared in a parallel system The cable connection method between each UPS and battery packs in a parallel system is the same as that for a single UPS Each 6 kVA 10 kVA UPS with standard backup time can connect to one ...

Страница 4: ... batteries in the positive battery string and that in the negative battery string connected to a UPS should be the same NOTE 1 When connecting the battery packs and the UPS connect cables in the following sequence as shown in the following figure a Connect the parallel cables between the positive battery packs and between the negative battery packs first b connect the cables between the UPS and th...

Страница 5: ...ling Cables Between Battery Packs and a 15 kVA 20 kVA UPS Parallel System 1 When the positive and negative battery strings of a 15 kVA 20 kVA UPS parallel system with long backup time consist of one battery pack respectively the charge current needs to be set to 2 A or less 2 The number of batteries in the positive battery string and that in the negative battery string connected to a UPS should be...

Страница 6: ...cks NOTE 5 No 1 battery pack in the positive battery string No 2 battery pack in the positive battery string No 3 battery pack in the positive battery string No 1 battery pack in the negative battery string No 2 battery pack in the negative battery string No 3 battery pack in the negative battery string No 4 battery pack in the positive battery string No 4 battery pack in the negative battery stri...

Страница 7: ...ute it through the short cables as shown in the left figure 5 Connect the negative battery cable of the battery string on the fuse board to the battery module wiring terminal 3 Install the battery module and reinstall the fastener of the fuse board with J2 upward 4 Install battery cables at one side and bind the cables as shown in the following figure 1 Remove the baffle plates from the top and re...

Страница 8: ...first and then connect the cables with parallel terminals of the batteries 6 Install the cable from the fuse board to the negative battery terminal 7 Install battery cables at the other side and connect the positive battery cable of the battery string to the battery module wiring terminal NOTE Huawei Technologies Co Ltd Huawei Industrial Base Bantian Longgang Shenzhen 518129 People s Republic of C...

Отзывы: