G-46 MDB
R
EMEDYING
FAULTS
41
National Rejectors, Inc. GmbH, Buxtehude
Display
FE-01
FE-02
FE-03
FE-04
FE-13
FE-14
FE-15
FE-38
Meaning
motor default, left tube
motor default, middle/left tube
motor default, middle/right tube
motor default, right tube
check sum error in acceptance bands
check sum error in coin values
check sum error in programming data
no communication with machine control
Remedy
press internal
L
-key
press internal
ML
-key
press internal
MR
-key
press internal
R
-key
check all programming functions using PC
software "WinEMP"
check all programming functions using PC
software "WinEMP"
check all programming functions using
setting module or PC software "WinEMP"
check connecting cable
The acceptance of a coin will also be indicated, which is in the form of "An
x yy". Here "yy" indicates the channel number and "x" the sorting of the coins
according to the following scheme:
0 = cash-box
1 = left tube
2 = middle/left tube
3 = middle/right tube
4 = right tube
Example:
„An 0 12“ = Coin accepted in channel 12 and sorted into the cash-box