VANE OPERATION AND CONSIDERATIONS
Output Circuit Operation
The Hybrid XT line of wind vanes are available with different output configurations to support a variety of turbine
control systems. See the appendices below for the output characteristics of the full suite of Hybrid XT vanes.
Hybrid XT Vane Head Damping
The Hybrid XT Vane has damping in the head to reduce overshoot and oscillation behind the turbine rotor. One result of
this is that the frequency response has been lowered slightly. This may, in some limited circumstances, require a slight
adjustment to the turbine controller settings when retrofitting a Hybrid XT in place of an IceFree 2, IceFree 3, or an
original Hybrid. Please contact Renewable NRG Systems for further information.
Finished
good #
Vane type
Output
wires
Function
Signal
type
Description
4715
Hybrid XT Turbine
Control Vane
White
Pulsed
output
Frequency
100Hz - 460Hz square wave for 0 - 360 degrees
5762
Hybrid XT 4-20
mA Output Vane
White
Current
source
4-20 mA
4-20 mA output, clockwise, corresponds to 0 - 360
degrees
7894
Hybrid XT Push-
Pull Vane, ACTIVE
LOW
White
VL
2-channel
push/pull
Yaw right/left (VL), upwind/downwind (VR90); active
LOW
Yellow
VR90
9362
Hybrid XT 4-20
mA Output Vane,
CCW
White
Current
source
4-20 mA
4-20 mA output, counter-clockwise, corresponds to
0 - 360 degrees
9363
Hybrid XT Push-
Pull Vane, ACTIVE
HIGH
White
VL
2-channel
push/pull
Yaw right/left (VL), upwind/downwind (VR90); same
as FG #7894, but active HIGH
Yellow
VR90