Shield wire to be cut or
attached to mast
Feed cable through mast.
Shield wire to be
cut or attached to
mast
Mount Connector
Remove the nut, washer, and bolt from the connector. Feed the cable through the mounting mast until the connector
reaches the mast. Align the bolt hole in the connecter with the holes in the mounting mast such that the “TOWARD
ROTOR” text molded onto the connector leg is oriented toward the turbine rotor. If you are connecting the shield to the
mounting mast, do so now.
Be sure that the connector is snug against the top of the mounting mast and that the washer is on the bolt (compression
of the rubber washer may be necessary) then pass the bolt though the mast and connector. Now attach the nut to the
bolt a few turns until the nylon patch is in contact with the nut. The nylon patch prevents the nut from backing off the
bolt threads. Note that the washer is between the mounting mast and the bolt head.
nut
washer &
bolt
Remove
the
nut, washer, & bolt.
Install connector with “TOWARD ROTOR”
text pointing to the rotor.
rubber
washer
“TOWARD
ROTOR” text on
connector leg
Secure connector to mast with bolt,
washer, and nut.
SS washer away
from mast to
allow sensor to
slide in place
Connector and
rubber washer
snug to mast