NRG INSTRUCTIONS
SRA System | Soiling Measurement Kit
SRA Soiling Measurement Kit Instructions
Rev. 6.0
[email protected] | Page 12
19 December 2018
SECTION 2: WIRING AND MOUNTING THE INTERFACE MODULE
The Soiling Measurment Kit comes with an Interface Module used to create usable data for your
SymphoniePRO data logger and mounts inside the FRP shelter box on the included DIN rail section.
Figure 2-1: Interface Module, cabling, DIN rail, mounting bolts & IMT Temp Sensor Instructions
2.1: Connect the 4C cable.
Attach the 4C cable to the Interface Module according to Table 2-1. The cable ends are labeled for
guidance.
Table 2-1
Wire Color
Interface Module Location
26-Channel Wiring Panel
16-Channel Wiring Panel
Black
GND
16-26
16, 17, 20-22
Red
EXC
16-19, 20-26
16, 17, 20-22
Orange
I
SC
CLEAN
16-19, 20-26
16, 17, 20-22
White
I
SC
SOILED
16-19, 20-26
16, 17, 20-22