4-2. Emitter Point Cleaning 

 

Remove filter cover from rear panel of main enclosure. 

 

Clean emitter points using cotton swab with DI water or Isopropyl Alcohol.

 Caution

, emitter points are 

very sharp. 

 

After cleaning, make sure ionizer is dry before turning power on. 

 

If there is any damage or excessive wear on the emitter point, it is recommended to replace it. 

Note: Cleaning requirements of emitter points will vary based on operating environment and use. 
Recommended cleaning interval is once a month to once every other month. 

4-3. Filter Cover Cleaning 

 

Remove filter cover from rear panel of main enclosure. 

 

Clean filter cover with water or compressed air. 

 

After cleaning, make sure ionizer is dry before turning power on. 

 

If there is any damage on the filter cover, it is recommended to replace it. 

Model 6211 Filter Cover                                                     Model 6212 Filter Cover 

                                   

 

 

4-4. Emitter Point Replacement 

 

Remove filter cover from rear panel of main enclosure. 

 

Remove emitter points from sockets by gently pulling toward the middle of the ionizer. 

Caution

, emitter 

points are very sharp, using tweezers or pliers is acceptable. 

 

Insert new emitter points into sockets by gently pushing in as far as it will go. 

Caution

, emitter points are 

very sharp, using tweezers or pliers is acceptable. 

Note: Emitter point useful life also varies based on operating environment and use. Recommended replacement 
interval is once a year to once every other year. 

 
 
5. Ionizer Status 

5-1. LED 

Topside LED gives indication of ionizer operation and alarm status. 

5-2. Audio Alarm 

Audible buzzer alarm gives recognition for user or operator 
 

Содержание Staticmaster 6211

Страница 1: ...nd Descriptions 1 1 Features 1 2 Descriptions 2 Installation 2 1 Basic Installation 2 2 Inside or Outside of Process Tool 2 3 Recommended Installation Guideline 2 4 Power Connection 3 FMS Connection 3 1 Interface Terminal Connection 3 2 Interface Terminal Cabling 2 2 4 4 4 Maintenance 4 1 Filter Cover Attach and Release 4 2 Emitter Point Cleaning 4 3 Filter Cover Cleaning 4 4 Emitter Point Replace...

Страница 2: ...and generates high voltage Do not open and modify it or operate without being completely assembled High voltage internal parts can cause electrical shock WARNING Before performing maintenance turn the Staticmaster off and disconnect from the power source High voltage internal parts can cause electrical shock WARNING Do not use this product in a flammable atmosphere WARNING Do not submerge in water...

Страница 3: ...l_03 15 1 2 Descriptions Model 6211 Model 6212 1 Operation LED Green LED indicates that the ionizer is working properly or normal condition 2 Alarm LED Red LED indicates that ionizer is in abnormal condition 3 ON OFF Switch Power ON OFF Switch 4 Stand Refer to section 8 for dimensions of the mounting holes 5 Knob Direct ionizer at target and tighten knob to hold ionizer in place ...

Страница 4: ...N OFF and Air Flow Switch Left High Middle Off Right Low 2 Installation 2 1 Locate the Staticmaster 300mm to 1200mm from the target to be neutralized for optimal performance making sure that the airflow will not be restricted A working electrical outlet within reach of the 1 8m 6 long detachable cord that is supplied with the Staticmaster 2 2 The Staticmaster can be installed in two different ways...

Страница 5: ... Open FMS 3 Balance Alarm relay output Alarm Closed 17 20mA Closed FMS 4 Current output for each operation Power OFF Closed 0mA Closed FMS 5 Current output reference ground FMS 6 Balance Relay common 3 2 Interface Terminal Cabling 4 Maintenance Turn power off prior to regular maintenance or emitter point cleaning 4 1 Filter Cover Attach and Release Model 6211 Press filter cover slightly on the sid...

Страница 6: ...n enclosure Clean filter cover with water or compressed air After cleaning make sure ionizer is dry before turning power on If there is any damage on the filter cover it is recommended to replace it Model 6211 Filter Cover Model 6212 Filter Cover 4 4 Emitter Point Replacement Remove filter cover from rear panel of main enclosure Remove emitter points from sockets by gently pulling toward the middl...

Страница 7: ...BS Black Bracket Aluminum Operating Environment Temperature 15 35 Humidity 35 85 RH Dimensions WxHxD 125x135x69 5mm with bracket 152x154 5x69 5mm Weight 571g with bracket Model 6212 Input Voltage 24V DC 13W Maximum Ion Emission Steady State DC Technology Balance 20V Discharge 1000V to 100V less than 2 seconds at 30cm 1000V to 100V less than 4 seconds at 60cm Air flow 140 CFM Maximum 151 CFM Emitte...

Страница 8: ...for a Return Authorization number and shipping instructions Include a copy of your original packing slip invoice or other proof of purchase date If the ionizer is out of warranty NRD LLC will quote repair charges necessary to bring your ionizer up to factory standards Warranty Exclusions The forgoing express warranty is made in lieu of all other product warranties expressed and implied including m...

Отзывы: