                                                                                                                                INSTNeutralizerAC – 1/19 

The battery should be charged completely prior to 
first use or if the green LED does not light when 
the trigger is depressed. 

 

Charge the battery as follows: 

 

Remove the safety key. (Do not discard, 
save to use later) 

 

 

 

Connect the DC battery plug to the Neutral-
izer

AC battery jack.

 

 

 

 

 

Connect charger to AC power source. 

 

LED indicator is Red when charging and 
Green when charge is complete. 

 

When charging is complete, disconnect 
charger from AC power source and then the 
Neutralizer

AC. 

 

When LED indicator is Green the battery charger 
will not over charge the battery. 

 

Installation and Operation 

 

Warranty Note: Failure to use clean, dry, filtered, 
compressed air will VOID warranty. 

 

Air filters remove oil, water, and other debris from 
compressed air that could impede performance of 
the Ionizing Blow Gun. 

 

1.

 

Attach the Ionizing Blow Gun to a 1/4” NPT 
hose fitting.  Screw the fitting securely into 
the base of the handle.  Use thread sealant as 
needed. 

2.

 

Connect and turn on compressed air to Ioniz-
ing Blow Gun. 

3.

 

Regulate the air pressure to desired level.  
Do not exceed an inlet pressure of 50 psig. 

4.

 

Remove the safety key. (Do not discard, save 
to use later) 

5.

 

Squeeze trigger to begin air flow and activate 
the Neutralizer

AC Ionizing Blow Gun.  

Green LED on top of Ionizing Blow Gun 
will be lit to verify the air ionizer circuitry is 
activated. 

6.

 

Move the Ionizing Blow Gun in a slow 
sweeping path, at a distance of 12”, covering 
the entire part.  A powerful stream of ionized 
air will flow over objects and quickly neu-
tralize electrostatic charges, remove dust and 
other foreign particulate clinging due to stat-
ic attraction. 

 

Note: Any contact, such as additional tacking, 
after the surface has been cleaned and ionized may 
result in re-charging the surface with static.  We 
recommend that you repeat the cleaning of the part 
with the Ionizing Blow Gun.  This ensures the 
static charges have been removed. 

 

 

 
 
7.

 

When the Neutralizer

AC Ionizing Blow 

Gun is not in use, use the ring to hang it from 
a hook.

 

 

 Battery jack 

 AC Plug 

 Safety key 

 DC Plug 

 LED Indicator 

 1/4” NPT 

 Trigger 

 Green LED 

 Tab 

 Tab 

 Air nozzle 

 Ring 

Содержание NeutralizerAC 6500

Страница 1: ...14072 0310 PHONE 716 773 7634 FAX 716 773 7744 EMAIL sales nrdllc com WEB www nrdllc com NRD Asia Pte Ltd 114 Lavender Street 08 90 CT Hub 2 Singapore 338729 PHONE 65 6679 1707 EMAIL sales NRDasia com WEB www nrdllc com INSTNeutralizerAC 1 19 Auto Body Refinishing Anti static Gun Model 6500 ...

Страница 2: ...arge This type of ionizer is simple to use and very efficient for removing static charges which can attract and hold onto dust and debris Corona ionization occurs when an electrical voltage is placed on a sharp point called an emitter pin In a properly designed AC alternating current ionizing device both positive and negative ions are pro duced making it capable of neutralizing either polarity on ...

Страница 3: ... hearing protection when operating the Neutralizer AC Ionizing Blow Gun 12 Do not submerge in water If water enters the Neutralizer AC allow it to thoroughly dry before using again 13 Do not leave the Neutralizer AC near a heat source 14 Do not disassemble or modify the Neutral izer AC except to change the emitter pin or filter High voltage internal parts can cause electrical shock 15 The operatin...

Страница 4: ...e Ionizing Blow Gun 1 Attach the Ionizing Blow Gun to a 1 4 NPT hose fitting Screw the fitting securely into the base of the handle Use thread sealant as needed 2 Connect and turn on compressed air to Ioniz ing Blow Gun 3 Regulate the air pressure to desired level Do not exceed an inlet pressure of 50 psig 4 Remove the safety key Do not discard save to use later 5 Squeeze trigger to begin air flow...

Страница 5: ...pending on the amount of use Additional re placement emitter pins are available by contacting NRD This ionizer is categorized as non shockless This means there is a High Voltage Shock Hazard Insert the safety key into the battery jack and attach the trigger lockout clip behind the trigger while maintenance is performed Also use cau tion whenever handling ionizers since the emitter pin is sharp and...

Страница 6: ...e cylinder back in with the arrow for air flow pointing toward the front of the blow gun Trouble Shooting Guide Symptom Probable Cause Corrective Action LED is not lighting Battery does not have sufficient charge Recharge battery Static charges are not eliminated Emitter pin is old or degraded Ions generated are being recom bined before they reach the charged surface Replace emitter pin The Neutra...

Страница 7: ... 108 EC Australia and New Zealand regulatory conformance NRD LLC hereby declares that this Neutralizer AC model 6500 device is in compliance with the essential requirements and other relevant provisions of Australian and New Zealand Standard AS NZS CISPR 11 2004 Additional regulatory conformance Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General ...

Отзывы: