Installation / Operation / Maintenance
NRD USA / 2937 Alt Boulevard / PO Box 310 / Grand Island, NY 14072-0310
PHONE
716 773 7634 /
FAX
716 773 7744 /
WEB
www.nrdllc.com
NRD Asia Pte. Ltd
/ 114 Lavender Street #08-90 CT Hub 2 Singapore 338729
PHONE
+65 6679 1707 /
WEB
www.nrdllc.com
INSTNeutralizerAC – 1/19
The battery should be charged completely prior to
first use or if the green LED does not light when
the trigger is depressed.
Charge the battery as follows:
Remove the safety key. (Do not discard,
save to use later)
Connect the DC battery plug to the Neutral-
izer
AC battery jack.
Connect charger to AC power source.
LED indicator is Red when charging and
Green when charge is complete.
When charging is complete, disconnect
charger from AC power source and then the
Neutralizer
AC.
When LED indicator is Green the battery charger
will not over charge the battery.
Installation and Operation
Warranty Note: Failure to use clean, dry, filtered,
compressed air will VOID warranty.
Air filters remove oil, water, and other debris from
compressed air that could impede performance of
the Ionizing Blow Gun.
1.
Attach the Ionizing Blow Gun to a 1/4” NPT
hose fitting. Screw the fitting securely into
the base of the handle. Use thread sealant as
needed.
2.
Connect and turn on compressed air to Ioniz-
ing Blow Gun.
3.
Regulate the air pressure to desired level.
Do not exceed an inlet pressure of 50 psig.
4.
Remove the safety key. (Do not discard, save
to use later)
5.
Squeeze trigger to begin air flow and activate
the Neutralizer
AC Ionizing Blow Gun.
Green LED on top of Ionizing Blow Gun
will be lit to verify the air ionizer circuitry is
activated.
6.
Move the Ionizing Blow Gun in a slow
sweeping path, at a distance of 12”, covering
the entire part. A powerful stream of ionized
air will flow over objects and quickly neu-
tralize electrostatic charges, remove dust and
other foreign particulate clinging due to stat-
ic attraction.
Note: Any contact, such as additional tacking,
after the surface has been cleaned and ionized may
result in re-charging the surface with static. We
recommend that you repeat the cleaning of the part
with the Ionizing Blow Gun. This ensures the
static charges have been removed.
7.
When the Neutralizer
AC Ionizing Blow
Gun is not in use, use the ring to hang it from
a hook.
Battery jack
AC Plug
Safety key
DC Plug
LED Indicator
1/4” NPT
Trigger
Green LED
Tab
Tab
Air nozzle
Ring