12
5.
Do not face battery when making final connection.
6.
Connect charger AC supply cord to electric outlet.
7.
Charge battery as outlined in
OPERATING
INSTRUCTIONS
section.
8.
When disconnecting chargers, always do so in reverse
sequence of connecting procedure and break first
connection while standing as far away from battery as
practical.
CHARGER CONTROLS
DIGITAL DISPLAY MODE SELECTION
Press the Display Mode button to toggle digital display content
as follows:
Current
– When selected, charging current (A) will be
displayed.
Voltage
– When selected, charging voltage (V) will be
displayed. The voltage displayed is the charging voltage
and usually will be higher than the battery’s resting voltage.
Battery Capacity %
- When selected, approximate
percentage of battery charge will be displayed.
o
At less than 50% battery capacity, the display will
read “LO”
o
The display will increase in 10% increments
between 50% to 90% capacity. Such as “80”.
o
At full charge, the display will read will read “FUL”