8000 Series User’s Manual, Release 1.3
Fig. 3.4: Plugging the switch into an outlet
3.3.1 Power Failure
As a precaution, the switch should be unplugged in case of power failure. When power is resumed, plug the
switch back in.
3.3.2 Grounding the Switch
This section describes how to connect the WebSmart Switch to ground. You must complete this procedure
before powering your switch.
Required Tools and Equipment
• Ground screws (included in the accessory kit): One M4 x 6 mm (metric) pan-head screw.
• Ground cable (not included in the accessory kit): The grounding cable should be sized according to
local and national installation requirements. Depending on the power supply and system, a 12 to
6 AWG copper conductor is required for U.S installation. Commercially available 6 AWG wire is
recommended. The length of the cable depends on the proximity of the switch to proper grounding
facilities.
• A screwdriver (not included in the accessory kit).
The following steps let you connect the switch to a protective ground:
Step 1
Verify if the system power is off.
Step 2
Use the ground cable to place the #8 terminal lug ring on top of the ground-screw
opening, as seen in the figure below.
Step 3
Insert the ground screw into the ground-screw opening.
Step 4
Using a screwdriver, tighten the ground screw to secure the ground cable to the switch.
Step 5
Attach the terminal lug ring at the other end of the grounding cable to an appropriate
grounding stud or bolt on rack where the switch is installed.
10
Chapter 3. Hardware Installation
Содержание N1-8016
Страница 1: ...8000 Series User s Manual Release 1 3 NPORT Networks INC February 15 2016...
Страница 2: ......
Страница 4: ...ii...
Страница 6: ...8000 Series User s Manual Release 1 3 2 Chapter 1 About This Guide...
Страница 16: ...8000 Series User s Manual Release 1 3 12 Chapter 3 Hardware Installation...
Страница 44: ...8000 Series User s Manual Release 1 3 40 Chapter 5 Appendix A Technical...