background image

ISO-STIM 01B User Manual 

version 1.8 

 

 

page 3 

1. Safety Regulations 

 

VERY IMPORTANT

:

 Instruments and components supplied by npi electronic are NOT 

intended for clinical use or medical purposes (e.g. for diagnosis or treatment of humans), 
or for any other life-supporting system. npi electronic disclaims any warranties for such 
purpose. Equipment supplied by npi electronic must be operated only by selected, trained 
and adequately instructed personnel. For details please consult the GENERAL TERMS 
OF DELIVERY AND CONDITIONS OF BUSINESS of npi electronic, D-71732 Tamm, 
Germany.

 

 
1)

 

GENERAL: This system is designed for use in scientific laboratories and must be operated 
by trained staff only. General safety regulations for operating electrical devices should be 
followed. 

 
2)

 

AC MAINS CONNECTION: While working with the npi systems, always adhere to the 
appropriate safety measures for handling electronic devices. Before using any device 
please read manuals and instructions carefully. 
The device is to be operated only at 115/230 Volt 60/50 Hz AC. Please check for 
appropriate line voltage before connecting any system to mains. 
Always use a three-wire line cord and a mains power-plug with a protection contact 
connected to ground (protective earth).  
Before opening the cabinet, unplug the instrument. 
Unplug the instrument when replacing the fuse or changing line voltage. Replace fuse only 
with an appropriate specified type. 

 
3)

 

STATIC ELECTRICITY: Electronic equipment is sensitive to static discharges. Some 
devices such as sensor inputs are equipped with very sensitive FET amplifiers, which can 
be damaged by electrostatic charge and must therefore be handled with care. Electrostatic 
discharge can be avoided by touching a grounded metal surface when changing or 
adjusting sensors. 

Always turn power off when adding or removing modules, 

connecting or disconnecting sensors, headstages or other components from the 
instrument or 19” cabinet.

 

 
4)

 

TEMPERATURE DRIFT / WARM-UP TIME: All analog electronic systems are sensitive 
to temperature changes. Therefore, all electronic instruments containing analog circuits 
should be used only in a warmed-up condition (i.e. after internal temperature has reached 
steady-state values). In most cases a warm-up period of 20-30 minutes is sufficient. 

 
5)

 

HANDLING: Please protect the device from moisture, heat, radiation and corrosive 
chemicals. 

 

Содержание ISO-STIM 01B

Страница 1: ...STEM DESCRIPTION FOR THE ISO STIM 01B STIMULUS ISOLATOR VERSION 1 8 npi 2016 npi electronic GmbH Bauhofring 16 D 71732 Tamm Germany Phone 49 0 7141 9730230 Fax 49 0 7141 9730240 support npielectronic com http www npielectronic com ...

Страница 2: ...e for High Voltage Instruments 4 3 ISO STIM 01 B 5 3 1 System Description 5 3 2 Description of the Front Panel 5 3 3 Description of the Rear Panel 8 3 4 ISO CAB optional accessory 8 3 5 Operation 9 3 5 1 Connections Noise Reduction 9 3 5 2 Operation Modes 9 4 Power Supply 10 5 Technical Data ISO STIM 01B 11 ...

Страница 3: ...ge before connecting any system to mains Always use a three wire line cord and a mains power plug with a protection contact connected to ground protective earth Before opening the cabinet unplug the instrument Unplug the instrument when replacing the fuse or changing line voltage Replace fuse only with an appropriate specified type 3 STATIC ELECTRICITY Electronic equipment is sensitive to static d...

Страница 4: ...er supplies to protective earth 2 Do not touch connections unless the instrument is turned off and the capacitance of both the load and power supply are earthed 3 Allow adequate time for discharge of internal capacitance of the power supply 4 Do not ground yourself or work under wet or damp conditions 5 Servicing should be only done by qualified personnel aware of the hazards 6 If in doubt return ...

Страница 5: ...T INPUT allows the pulse length to be externally controlled whereas amplitude and polarity are controlled by the device itself For both timing modes the generated pulses can be unipolar or bipolar In bipolar mode an interphase gap IPG of adjustable length can be inserted between the two pulses 3 2 Description of the Front Panel Figure 1 Front panel view of ISO STIM 01B In the following description...

Страница 6: ...MODE the limit 100 V is set by the corresponding voltage at the electrode due to Ohm s Law V I R i e this control indicates during an experiment in CURRENT OUTPUT MODE that the electrode resistance increases and the amplifier is not be able to provide the current which is set if the electrode resistance increases further 8 STIM LED LED indicating the application of a voltage or current stimulus 9 ...

Страница 7: ...nge to be set with the AMPLITUDE potentiometer 5 16 IPG TIME µs potentiometer with switch Potentiometer to select the interphase gap time IPG in bipolar stimulation mode see 3 5 2 IPG is turned off in the leftmost position switch 17 DIRECT INPUT TTL BNC connector A TTL signal can be fed in here to trigger the output of the ISO STIM 01D Amplitude will be set by 5 6 15 In unipolar mode 4 the output ...

Страница 8: ...ector are connected to the ISOLATED OUTPUT connectors on the front panel of the ISO STIM 01 D Each of these stimulation lines has a shield which is connected to the common green SHIELD connector To reduce noise during recordings this connector can be connected to the CHASSIS connector at the ISO STIM 01 D front panel The other end of the cable provides open wires to which different connector types...

Страница 9: ...ed the whole slice will be stimulated resulting in a DC shift of the whole slice 3 5 2 Operation Modes BIPOLAR The isolator is capable to generate biphasic stimuli by switching the stimulus mode switch to BIPOLAR ON In this mode the stimulus that is set by the user will be followed by a second stimulus with the same amplitude and duration but with reverse polarity There is no delay between first a...

Страница 10: ...left and rear panel right view of the ISO STIM 01B power supply The power supply is connected to mains with a standard power cord It has a POWER ON switch on the rear panel Important Only use the supplied power supply to power the ISO STIM 01B Using different power supplies might result in damage of ISO STIM 01B and or power supply Important This power supply is designed for use with the ISO STIM ...

Страница 11: ...bipolar selected by toggle switch Output voltage 100 V max isolated Output current 10 mA max isolated IPG interphase gap 50 500 µs Power requirements 100 240 V AC only use supplied power supply Fuses Power Supply 1 25 A slow Dimensions ISO STIM 01B 246 x 188 x 89 mm W x D x H Power Supply 103 x 169 x 59 mm W x D x H ...

Отзывы: