MEDICAL DEVICE INTERFERENCE

GyroSet Link contains an IEEE 802.15.4 Standard compliant 2.4 GHz RF transceiver 

that emits electromagnetic radiation. This electromagnetic radiation may interfere 

with pacemakers, defibrillators, or other medical devices. Maintain a safe distance of 

separation between your medical device and the GyroSet Link. Consult your physician 

and medical device manufacturer for information specific to your medical device. If 

you suspect your GyroSet Link is interfering with your pacemaker, defibrillator, or any 

other medical device, stop using GyroSet Link.

Now Technologies Ltd. hereby declares that this wireless device is in compliance with 

the essential requirements and other relevant provisions of the RED Directive and 

Radio Equipment Directive 2014/53/EU, as applicable.

WARRANTY

Now Technologies Ltd. provides one year’s full warranty on the products. This warran-

ty covers any defects in materials or workmanship, with the exceptions stated below:

Faults resulting from the installation by an unqualified person. Any problem that is 

caused by abuse, misuse, extreme water damage or extreme weather are not covered. 

Also, consequential and incidental damages are not recoverable under this warranty.

MEDICAL DEVICE INTERFERENCE

GyroSet Glory contains components and radios that emit electromagnetic radiation. 

This electromagnetic radiation – although unlikely - may interfere with pacemakers, 

defibrillators, or other medical devices. Maintain a safe distance of separation be

-

tween your medical device and the GyroSet Glory. Consult your physician and medical 

device manufacturer for information specific to your medical device. If you suspect 

your GyroSet Glory is interfering with your pacemaker, defibrillator, or any other medi

-

cal device, stop using GyroSet Glory.

4

Содержание Gyroset Link

Страница 1: ...emarks of Now Technologies Ltd registered in 18 Re ltanoda street Budapest 1053 Hungary European representative of the Manufacturer Now Technologies Ltd 18 Re ltanoda street Budapest 1053 Hungary www...

Страница 2: ...2...

Страница 3: ...s in life support and or safety applications is entirely at the buyer s risk and the buyer agrees to defend indemnify and hold harmless Now Technologies from any and all damages claims suits or expens...

Страница 4: ...able WARRANTY Now Technologies Ltd provides one year s full warranty on the products This warran ty covers any defects in materials or workmanship with the exceptions stated below Faults resulting fro...

Страница 5: ...ystem Before proceeding please make sure that one of the compatible devices are already installed on the chair and working properly For more information on how to set up the Omni please follow the ins...

Страница 6: ...ure has two M4 sized screw threads on the back of the device that is designed specifically for mounting As every vehicle and user is unique there is no general mounting bracket available Dimensions an...

Страница 7: ...nto the connector When there is no intention to use the wired interface please leave the connector s silicon cap in place Placement shall avoid the closeness of any magnetic materials or large iron pa...

Страница 8: ...r the headset data cable must be accessible to allow the caretaker to plug in or out the cable GyroSet Link should be placed as such that the Status LED logo is visible for at least the caretaker pref...

Страница 9: ...hat would surpass the power limitation and prevent the system from operation For the above reason if the Omni is configured with programmable parameter Sleep 12V to cut the power on SID connectors whe...

Страница 10: ...input device connected to the Omni is Port 1 as shown on the picture below In case of PGDT IOM there is only one INPUT port where the D type connector can be connected Connecting the GyroSet Link to...

Страница 11: ...ble to the GyroSet Glory Please make sure that the wiring meets the following criteria The GyroSet Link must be properly connected to PGDT Omni or IOM Cable that connects to the wheelchair controller...

Страница 12: ...come disconnected a screen will appear on the Omni with error code 0905 WARNING Always make sure that the chair is configured in a way that the chair s on off switch is available to the user according...

Страница 13: ...es There are three methods of programming the Omni Details of the actual programmable parameters are given in the SK78813 Programming chapter Ensure the R net Control System s Drive Acceleration and D...

Страница 14: ...PC programmer to configure Omni Port 1 SID has to be set to propor tional To use the Click sensor of the headset to activate menu functions on the Omni Port 1 User control has to be set to Menu and Re...

Страница 15: ...set User control is set Drive Acceleration and Deceleration settings are at a comfortable and safe level GYROSET LINK CONFIGURATION In this document we presume that the user is already familiar with...

Страница 16: ...IVING 1 Imagine that Your head will act like a regular joystick 2 Press the headset s mode button shortly against the headrest then return Your head into a neutral position and keep it there until the...

Страница 17: ...g criteria are met before trying to drive the wheel chair with the GyroSet Link Understanding of the intended use of the headset by getting familiar with the GyroSet Glory Headset s User Manual The ad...

Страница 18: ...f the Personal Area Network must be changed frequently The password must be chosen carefully it should contain lower and upper case letters symbols and numbers The password must be minimum 8 ideally 1...

Страница 19: ...When fifth button function is programmed so that the User can control actuators the headset will control If the GyroSet Link is mounted to a part that stays in level when the backrest is tilting it wo...

Страница 20: ...ir If the Users head reaches the end of the range of operation the sweep of the head joystick is at maximum If the Users head reaches the safety zone the chair will stop If the Users head is in the ra...

Страница 21: ...et Blue Breathing fade in fade out Connection to the headset established through RADIO and IDLE Blue Blinking Connection to the headset established through RADIO and ACTIVE Green Breathing fade in fad...

Страница 22: ...System halted Software update Currently there is no possibility for the end user nor the distributor to update the firmware To update the software on the Gyroset Link the device has to be disassem ble...

Страница 23: ...tects human health and the environment EXPOSURE TO RADIO FREQUENCY The GyroSet Glory has been tested and meets applicable limits for radio frequency RF exposure Specific Absorption Rate SAR refers to...

Страница 24: ...h hu ROHS DECLARATION OF CONFORMITY We hereby declare that our products are compliant to RoHS Directive 2011 65 EU of the European Parliament and the Council from 08 06 2011 on restriction of the use...

Отзывы: