B axis Coordinate C axis Coordinate
Ready:ReadyMode.In the mode we can do any operation,include processing or values
modification or starting 2nd mode.
Reset: Reset mode.In this mode,it should stop every operation.
“Step”:Manual Step Mode. Every axis candonduct the manual step operation at this mode.
MPG: MPG mode.Every axis can conduct the MPG operation at this mode.
1.5 Noting and Waring
Free from exposure to the electronics without waterproof
function.Please environment as dry as possible. This is the icon.
Wiring warning, the IO input terminal of this equipment support the
equipment with source switch (such as Inductive proximity switch.)When using such
kind of switch, attention please: avoid the +terminal and –terminal of power supply
to connect with GND.This equipment’s analogy quantity output terminal of
spindlecontrolalos have a certain load capacity. Please avoid this terminal connect with
GND.in case that the interior components and parts be brokendown.
Operation warning, Please do the security measures well when connecting
with the machine tools.The ESTOP, limit and other things must be perfected.When
comes across the emergancy, please press the ESTOP key at once or cut off the power directly,
thus avoiding the equipment damage and casualty.
High voltage danger, the primary device is 18-32VDC power supply.Voltage
equipment.Pls pay attention to the electricity, safety when conducting the operation