![Novusun CNC NVCM Series Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/novusun-cnc/nvcm-series/nvcm-series_manual_1713376025.webp)
Chapter4 Setting of softwar
e
Manual of NVCM
- 23 -
Figure4-10.
Spindle Settings dialog
Here we can configure the spindle rotates
、
CW Reverse
、
、
CCW Mist Flood pin, See as
Figure4-10
,
They have been configured
、 、 、
as 1 2 3 4. Corresponding to output#1~output#4 in
Figure4-11.output#1~output#6 in Output Signal Setup dialog can be Configured into these 4
signals. Here we only configure CW/MIST/FLOOD. CW is controlled by OUT1. MIST is
controlled by OUT2. Flood is controlled by OUT3. Here we note correspondence between 2
page. Please select “use spindle motor output” if required PWM speed spindle. And select “ PWM
Control”. Our PWM pin fixedly arranged on a special pin on Stepper motor setting dialog.
Figure4-11.
Spindle setting corresponds to the output configuration