NVIP-TDN5410C/MPX1.0, User’s manual ver.1.0.
All rights reserved © AAT Holding sp. z o.o.
11
The recommended way to start an IP camera and perform its configuration is a connection through
crossover cable with your PC or laptop. To obtain further information about network configuration
parameters (IP address, gateway, network mask, etc.) please contact your network administrator.
Network configuration of camera can be done by web browser or NMS software using default network
IP address: 192.168.1.200
2.5. Initial configuration via the web browser
1. IP address=
192.168.1.200
2. Network mask -
255.255.255.0
3. Gateway -
192.168.1.254
4. User name -
root
5. Password -
pass
Knowing the camera’s IP address you need to appropriately set PC IP address, so the two devices can
operate in one network subnet ( e.g. for IP 192.168.1.1, appropriate address for the camera ranges from
192.168.1.2 to 192.168.1.254, for example 192.168.1.60). It is not allowed to set the same addresses for
camera and PC computer
You can set network configuration (IP address, gateway, net mask, etc.) of NOVUS IP camera or select
DHCP mode (DHCP server is required in this method in target network) by using web browser or by
NMS software. When you use DHCP server check IP address lease and its connection with camera
MAC address to avoid changing or losing IP address during device operation or network/DHCP server
breakdown. You have to remember to use a new camera IP address after changing network parameters.
After network setting configuration has been done, the camera can be connected to a target network.
START-UP AND INITIAL CAMERA CONFIGURATION
Cross-over cable
IP camera
PC