NV-DVR4508(S)/DVD / NV-DVR4516(S)/DVD 1.1
version - User’s manual short form
All rights reserved © NOVUS Security Sp. z o.o.
10
2.2. Electrical connection and other back panel elements
STARTIG THE DEVICE
1.
VIDEO IN/LOOP
8 or 16 video inputs, with looped outputs, to connect cameras.
2.
VIDEO OUT
output to connect main monitor
3.
SPOT 1~4
outputs to connect up to 4 spot monitors. Each spot monitor can display full
screen image from one camera or from cameras in sequence
4.
Cooling fan (DO NOT COVER!!!)
5.
ARI (Alarm Reset Input):
external input signal connected to ARI and GND sockets. The
signal voltage should be above 0,3V longer than 0,5s to deactivate alarm
output.
PANIC
external input signal connected to PANIC and GND sockets. The signal
activates or deactivates alarm recording.
6.
RS-485
RS-485 connector for PTZ camera control or system keyboards
7.
Power supply socket 230V AC. Please make sure that the plug is inserted
correctly and cable is connected to a socket with a grounding pin. It is not
recommended to strongly bend the cable .
7
2
3
1
4
5
6
NV-DVR4516