RAID CONTROLLER
After a fault signal check which drive the problems in the
"MegaRAID Storage Manager "
will be a
yellow exclamation point in the status field, talking about the problem with the array. Please check
that the drive requires intervention and proceed to the physical drive replacement, the exchange in the
"phisical"
appears replaced hard with a red marker. After you select the drive, right
-
click, se-
lect
"Start Rebuild"
. Then, in the
"Dashboard"
in the
"Background Operations"
Filmaster status
can be monitored rebuild. After pressing the
"More details"
will be a plaque with a belt and
approximate time of restoration array. During the rebuilding of RAID is working with a smaller
capacity. Rebuilding can take anywhere from a few to several hours, depending on the size of the
disk.