LogBox-RHT-LCD 

 

NOVUS AUTOMATION 

2/6

 

2.1

 

MEASUREMENT ACCURACY 

 

Figure 2 –

 

Accuracy

 

Figure 3 –

 

Logger front (CH1) 

Channel Indicator

: Indicates the channel selected. 

Battery Indicator

:  When the battery voltage is low, the battery 

symbol will be shown. 

MIN / MAX Values Indicator

Minimum

  and 

maximum 

value of 

each channel during readings. 

3

 

OPERATION 

To use the device, you must install the NXperience software on a 

PC, according to the steps described in the 

NXPERIENCE 

SOFTWARE 

section. 

The communication between logger and PC is performed with a 

IR-

Link Interface

The logger operation mode set up is defined by using 

NXprience 

software. The configuration is sent to the logger through the 

IR-Link 

Interface

The logger starts and ends the acquisitions according to the 

configuration made. 

3.1

 

REGISTER SCREENS 

BATTERY SAVING MODE –

IDLE

 

Low battery consumption mode. The logger does not communicate. It 

always stays in this mode after reset; register does not make 

acquisitions and does not up-date screen measures. For skipping 

idle

  mode, press 

  button  for activating communication 

temporarily. After an acquisition configuration has been sent, it will 

definitely be out of 

idle

 mode. 

 

Battery Saving Mode

 

MAIN SCREEN 

Indication screen for values measured by the register: 

 

 

1st Screen 

– Temperature and      

Humidity 

2nd Screen 

– Temperature and dew 

point 

INDICATOR SCREEN MIN / MAX – CH1 

It indicates the minimum and maximum value of 

Chanel 1

 during the 

acquisitions. 

 

 

3rd Screen 

– CH1 Minimum Value 

4th Screen 

– CH1 Maximum Value 

INDICATOR SCREEN MIN / MAX – CH2 

It indicates the minimum and maximum value of 

Chanel 2

 during the 

acquisitions. 

 

 

5th Screen 

– CH2 Minimum Value 

6th Screen 

– CH2 Maximum Value 

COMMUNICATION SCREEN IR - COM 

It sets IR communication to automatic or manual: 

 

In the 

automatic 

mode  (

aut

),  communication will  be 

always active. For communicating, just direct the interface 

and use 

NXperience 

or 

LogChart II

  software.  It always 

stays in this mode after 

reset

 

In the 

manual

 mode (

nnan

) communication will be active 

20 seconds, after pressing the 

  button. During  this 

time, a communication shall be initiated for keeping the IR 

Communication active. 

 

 

7th Screen 

– IR Communication Screens 

 
DISPLAY UPDATING INTERVAL SCREEN - 

DISP

 

Содержание LogBox-RHT-LCD

Страница 1: ... finished or while they are not started Alarm Indicator AL1 and or AL2 This indicator informs you of alarm situations that have occurred and will be active whenever an alarm situation occurs It will remain in this condition until a new configuration is applied to the logger IR Communication Window COM This indicator is activated when a communication attempt is made or when communication between th...

Страница 2: ...sures For skipping idle mode press button for activating communication temporarily After an acquisition configuration has been sent it will definitely be out of idle mode Battery Saving Mode MAIN SCREEN Indication screen for values measured by the register 1st Screen Temperature and Humidity 2nd Screen Temperature and dew point INDICATOR SCREEN MIN MAX CH1 It indicates the minimum and maximum valu...

Страница 3: ...l is equal to 10 minutes and disp screen is in lo6 mode in every 1 minute a measure will be made to make the 10 necessary measures for an acquisition In this case consumption will be same as Ex 2 Example 4 Starting and ending of acquisitions It has to observe the best start and end acquisitions mode to save battery due to necessity of the measures If the process in which the measures are performed...

Страница 4: ...perature supported by the device Upper Alarm Allows you to enable and configure a higher alarm setpoint option available only if the Start Mode is set to Immediate Start or Date Time o Maximum Displays the maximum temperature supported by the device Lower Setpoint When the measured temperature is lower than the value set in this parameter the device will start the logs option available only if the...

Страница 5: ...t be interrupted following the device configuration 7 4 1 DOWNLOADING DATA Data download is accomplished by clicking the button Download Logs in the Download screen from NXperience During data transference a status bar indicates remaining data to be transferred Data downloading time is proportional to the number of readings logged 7 4 2 VISUALIZING DATA At the end of values transfer the data will ...

Страница 6: ...act with the electronic circuitry due to the risk of damage from static electricity Carefully check the battery polarity When closing the housing the cover must be properly tightened back in its place such as to assure the sealing protection Used batteries should not be recharged dismantled or incinerated After use batteries must be disposed according to local legal rules or returned to supplier N...

Отзывы: