NOVOTEST TP-2020 Скачать руководство пользователя страница 1

 

 

 

 

 

Coating Thickness Gauge  

NOVOTEST TP-2020

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 

Operating Manual 

 

2021

 

 

 

Содержание TP-2020

Страница 1: ...Coating Thickness Gauge NOVOTEST TP 2020 Operating Manual 2021...

Страница 2: ...llation 11 2 2 3 Probe connection 11 2 3 Intended use 12 2 3 1 Turning on 12 2 3 2 Working in MEASUREMENT mode 13 2 3 3 Zeroing of the probe 14 2 3 4 Working in CALIBRATION mode 15 2 3 5 Working in AR...

Страница 3: ...27 3 3 Warranty 27 3 3 1 Basic warranty 27 3 3 2 Extended warranty 27 3 3 3 Warranty for repaired or replaced parts 28 3 3 4 Wearing parts 28 3 3 5 Owner obligations 28 3 3 6 Warranty restrictions 29...

Страница 4: ...ruction and actions as well as information necessary for the correct use of the product Before use study this document as the device is to be used by those familiar with the principles of operation an...

Страница 5: ...1 2 V Amperage max mA 100 Time of continuous operation min h 20 Weight of the electronic unit and battery max g 250 Weight of the probe max g 150 Operating temperature C 20 40 Air humidity max 98 at...

Страница 6: ...is indicated in the passport of the device 1 4 Application of probes Fig 1 1 show the probes of different types F 0 3 F 0 5 F 2 F 5 NF 2 M 12 M 30 M 60 DSH ST STMD Figure 1 1 Probes F probe The probe...

Страница 7: ...oatings M30 0 30000 m 0 03h 0 02 mm Testing of mastic coatings M60 0 60000 m 0 03h 0 03 mm Testing of mastic coatings NF 2 0 2000 m 0 03h 0 002 mm Testing of anodic oxide films and paint coatings ST 4...

Страница 8: ...he keyboard buttons and their functions turning on and off left functional button right functional button navigation up in the device menu selection of the measuring unit navigation down in the device...

Страница 9: ...sessed by checking the modes of its operation and checking the possibility of measuring the thickness by the thickness blocks reference blocks The discrepancy between the readings of the device should...

Страница 10: ...ure that there is no mechanical damage to the processing unit 4 probe 10 connector 7 and connecting cable 9 2 2 2 Battery installation Place a battery into the battery compartment 5 after pushing and...

Страница 11: ...rasp its housing in a corrugated area do not pull the cable Figure 2 3 Manipulating connectors 2 3 Intended use 2 3 1 Turning on Turn the device on by pressing on the control panel until a short term...

Страница 12: ...ic display The measured data can be displayed in several modes see c 1 7 button is used to switch between the modes and when the button pressed the menu of displaying modes will appear on the screen N...

Страница 13: ...ed part 2 Then set the probe on the prepared sample or object without coating upright and push it down fig 2 11 without wiggling Figure 2 11 Setting of the probe on the uncoated object Warning Do not...

Страница 14: ...l corresponds to the base material of calibration Ferromagnetic base Non ferromagnetic base Base 1 Base 2 for a specific material of coating Dielectric coating Coating 1 Coating 2 Coating 3 Coating 4...

Страница 15: ...of the following parameters fig 2 17 LANGUAGE selection of the language of the device menu English Russia and others are available BRIGHTNESS changing of the display brightness from 0 to 100 discrete...

Страница 16: ...ttings of the probe This is needed to resume proper calibration after incorrect settings 2 3 7 2 Downloading of calibration backups The saved calibrations can be downloaded from the probe memory This...

Страница 17: ...e firmware version 2 3 9 Measurements 1 Connect the probe and turn the device on by pressing 2 Zero the probe see c 2 3 3 3 Set the probe on the test object or coated part upright and press it to down...

Страница 18: ...pressing 5 Check the accuracy of zero setting and make sure that the readings of the device do not exceed 2 m 6 Measure the test object If the coating thickness is identical to the coating thickness o...

Страница 19: ...nnect the DSH probe to the device 2 2 3 2 Turn the device on 2 3 1 3 Set the base material in the device settings Non ferromagnetic base and set the coating material to Dielectric coating 4 Set zero o...

Страница 20: ...old 2 4 Connection of the device to PC 2 4 1 Software installation Connecting the device to a PC user can transfer the information stored on the memory card to a PC To connect the device to a PC 1 Cop...

Страница 21: ...play 2 4 2 Working with AWP TP1M software At the first start of the program the window will appear where the archive location should be chosen for saving of the measurement information fig 2 32 and th...

Страница 22: ...and Russian websites or planet international website in English and the website will be opened in the browser by default 2 4 3 Data transfer to PC To drop the data saved in the device memory connect t...

Страница 23: ...rements to a PC 2 4 4 Data processing on PC In OPERATION WITH ARCHIVE section user can view print copy move and delete the data from archive fig 2 35 Each record is saved with a full information about...

Страница 24: ...DIAGRAM HISTOGRAM and measurement results Maximum Minimum Deviation Average Standard deviation Mean square deviation Variation coefficient The homogeneity of the series Number of measurements This inf...

Страница 25: ...he preview window of the testing protocol In the Screen copies section user can save the display images on the device in real time and the device should be connected to a PC To save the measurement pr...

Страница 26: ...The following warranty information is valid for all NOVOTEST products The manufacturer guarantees the conformity of the device to the requirements of the technical conditions under the user s complian...

Страница 27: ...e replaced adjusted due to the damage However these parts are subject to the basic warranty of NOVOTEST for 12 months probes and their components connecting cables parts and mechanisms exposed to mech...

Страница 28: ...turer Use of batteries or other components of poor quality Power line surge Failure a timely repair of damage found during scheduled maintenance Factors outside the scope of control of NOVOTEST for ex...

Страница 29: ...warranty repair of the device So always make sure that the authorized service center of NOVOTEST puts a stamp in the right place under the record about the performed procedure Table 3 1 The maintenanc...

Страница 30: ...place of storage should be free from vapors of aggressive media acids alkali and direct sunlight The device shall not be exposed to rapid shocks falls or strong vibrations The devices shall be placed...

Страница 31: ...______________________ __________________________________________________________________________________ __________________________________________________________________________________ ___________...

Отзывы: