background image

-  determine  the  angular  value  of  the  object  by  the  scale  of  angles  of  elevation  and  by  the  scale  of 

traversing angles; 

- determine range D by the angular value of the object from the table. For drawing up such tables one 

uses formula: 

 
 

 

 

R =         x  1,000 , 

 
where:    R - the range in metres; 
 

S - the known size of the object in metres; 

 

A - the angular value of the object in mils;  

 

1,000 - the factor which converts the angular value in mils  

 

 

into the abstract value 

 

7  MAINTENANCE 
 

The faultless operation and longevity of the device service life depends to a considerable extent on its 

regular checking and maintenance. 

During  use  of  the  device  it  is  necessary  to  check  its  technical  condition  in  due  time  with  the  aim  of 

detection and elimination of its derangements. The technical condition of the device is characterized by its 
good order, completeness and readiness for use. 

The list of operations in checking the device technical condition is given in tab. 3. 
Table 3 
 

What is checked, what tools, 

instruments and equipment are used. 

Method of checking 

 

Technical requirements 

 

The 

device 

completeness 

in 

compliance with the list of complete set. 
Check it by visual inspection 
 

The  complete  set  must  be 
fully available 
 

2  The  outer  appearance  of  the  device 
and  its  parts,  reliability  of  securing  of 
units,  mechanisms  and  parts.  Check  it 
by  visual  inspection,  testing  by  hand 
and using tools from the single STA kit 
 

No  cracks,  dents,  traces  of 
corrosion  and  other  defects 
must be on the outer surfaces 
of the device. 
All  units,  mechanisms  and 
parts must be reliably secured 

3 Integrity of the lenses of the eyepieces 
and  objectives,  light  filters  and  the 
condition  of  the  level  vial.  Cleanness  of 
the  outer  surfaces  of  the  optical  pieces. 
Check it by visual inspection 
 

The  optical  pieces  must  be 
intact and clean 
 

4  The  condition  of  the  headrest  and 
reliability  of  its  fastening.  Checking  is 
performed  by  visual  inspection  and 
testing by hand 
 

The headrest must be in good 
order. 
The 

displacement 

of 

the 

headrest after clamping  is  not 
allowed 

5  The  condition  of  silica  gel  in 
desiccators. 

Check 

it 

by 

visual 

inspection 
 

Silica gel must be bluish 
 

6 Smoothness of extension of the tripod 
legs. Check it by testing by hand 
 

The  tripod  legs  must  be 
extended  over  the  whole 
lenght  smoothly,    without 
seizing 
 

7  The  operation  of  the  mechanism  of  The 

operation 

of 

the 

Содержание PNB-3

Страница 1: ...Federal State Unitary Enterprise Production Amalgamation Novosibirsk Instrument Making Plant BINOCULAR OBSERVATION DEVICE PNB 3 SOKOL Service manual AL3 803 100 RE...

Страница 2: ...servation and determination of angular coordinates of objects observed from the stationary and temporary observation posts by day and night by the light of searchlights As distinct from PNB 3 1 device...

Страница 3: ...old 10 field of view deg 7 resolution in the centre of the field of view 5 range of measuring the angles deg elevation from minus 18 to 84 the traversing angles 360 Tell tale pipe magnification fold 8...

Страница 4: ...15 9 of the tripod 6 2 of the system of illumination 0 44 of the accumulator in the housing 2 of the device packed 53 12 50 3 COMPLETE SET Table 2 Name Value PNB 3 PNB 3 1 Observer s binoculars 1 1 T...

Страница 5: ...lar observation device PNB 3 Service manual 1 1 1 Nickel cadmium accumulators of NK 13 type Maintenance instructions 1 4 SAFETY PRECAUTIONS The device should be reliably secured at the seat of the tri...

Страница 6: ...sight in the vertical plane are read in the range from minus 18 3 00 to plus 84 14 00 from scale 7 and by the nonius secured rigidly in the bracket Readings are taken from the scale through the port...

Страница 7: ...optical pieces of the device Mount the headrest on the device Fix the lamp holders at the seats of the eyepieces of the binoculars and tell tale pipe In operation at night connect the plug coupling t...

Страница 8: ...e value of correction in divisions of the deflection which is added to the result obtained before Example It is required to take readings from the scale of the horizontal limb in compliance with figur...

Страница 9: ...e completeness in compliance with the list of complete set Check it by visual inspection The complete set must be fully available 2 The outer appearance of the device and its parts reliability of secu...

Страница 10: ...peration of the mechanisms of angles of elevation and traversing angles Check it by rotation of the device around the horizontal and vertical axes with the use of handles 6 Figure 1 The rotation must...

Страница 11: ...torage It is not permitted to store the device on the floor near stoves at the windows The premises where the device is stored must be dry and heated The air temperature in the premises must be not lo...

Страница 12: ...tored silica gel must not be exposed to the open air for more than two minutes to avoid saturation of silica gel with moisture from the surroundings Silica gel can be restored unlimitedly in doing so...

Отзывы: