background image

setting  the  eyepieces  by  the  observer’s 
interpupillary  distance.  Checking  is 
performed  by  rotation  of  handwheel  14 
(Figure 1) 
 

mechanism  of  setting  the 
eyepieces by the interpupillary 
distance  must  be  smooth,  
without  seizing  and  ensure 
the setting of the interpupillary 
distance  in  the  range  from  59 
to 72 mm 
 

8  The  run  of  the  eyepieces  and 
possibility  of  their  setting  in  the  rangeof 
the  diopter  scales.  Checking  is  carried 
out by rotation of scales 10 (Figure 3) 
 

The run of the eyepieces must 
be  smooth,  without  clearance 
and seizing and setting to any 
value  of  the  diopter  scale 
must be ensured 
 

 

 
Continuation of the tab. 3 
 

What is checked, what tools, 

instruments and equipment are used. 

Method of checking 

 

Technical requirements 

 

9  The  operation  of  the  mechanisms  of 
angles  of  elevation  and  traversing 
angles.  Check  it  by  rotation  of  the 
device  around  the  horizontal  and 
vertical  axes  with  the  use  of  handles  6 
(Figure 1) 
 

The  rotation  must  be  smooth, 
without jerks and seizing 
 

10  The  breaking  devices.  Checking  is 
carried out by testing by hand 
 

The  braking  devices  must 
ensure reliable fixation 
 

 
 
 

8  POSSIBLE  DERANGEMENTS  AND  METHODS   
    OF  THEIR  ELIMINATION

 

 
Table 4 
 

Derangement, outer 

display and additional 

symptoms 

 

Probable cause 

 

Method of elimination 

 

1  The  terrain  image  is 
visible weakly through the 
device 
 

Dust and dirt on the 
outer  surfaces  of 
the optical pieces 
 

Wipe 

the 

outer 

surfaces  of  the  optical 
pieces  by  using  a 
tissue 
 

 

Sweating 

of 

the 

optical pieces 
 

Blow  the  device  with 
dry 

air. 

Check 

its 

tightness.  Replace  the 
desiccators  with  new 
ones 
 

Silica 

gel 

in 

the 

desiccators becomes pink 
 

Silica 

gel 

is 

saturated 

with 

moisture 

Replace 

the 

desiccators with a new 
ones 

Содержание PNB-3

Страница 1: ...Federal State Unitary Enterprise Production Amalgamation Novosibirsk Instrument Making Plant BINOCULAR OBSERVATION DEVICE PNB 3 SOKOL Service manual AL3 803 100 RE...

Страница 2: ...servation and determination of angular coordinates of objects observed from the stationary and temporary observation posts by day and night by the light of searchlights As distinct from PNB 3 1 device...

Страница 3: ...old 10 field of view deg 7 resolution in the centre of the field of view 5 range of measuring the angles deg elevation from minus 18 to 84 the traversing angles 360 Tell tale pipe magnification fold 8...

Страница 4: ...15 9 of the tripod 6 2 of the system of illumination 0 44 of the accumulator in the housing 2 of the device packed 53 12 50 3 COMPLETE SET Table 2 Name Value PNB 3 PNB 3 1 Observer s binoculars 1 1 T...

Страница 5: ...lar observation device PNB 3 Service manual 1 1 1 Nickel cadmium accumulators of NK 13 type Maintenance instructions 1 4 SAFETY PRECAUTIONS The device should be reliably secured at the seat of the tri...

Страница 6: ...sight in the vertical plane are read in the range from minus 18 3 00 to plus 84 14 00 from scale 7 and by the nonius secured rigidly in the bracket Readings are taken from the scale through the port...

Страница 7: ...optical pieces of the device Mount the headrest on the device Fix the lamp holders at the seats of the eyepieces of the binoculars and tell tale pipe In operation at night connect the plug coupling t...

Страница 8: ...e value of correction in divisions of the deflection which is added to the result obtained before Example It is required to take readings from the scale of the horizontal limb in compliance with figur...

Страница 9: ...e completeness in compliance with the list of complete set Check it by visual inspection The complete set must be fully available 2 The outer appearance of the device and its parts reliability of secu...

Страница 10: ...peration of the mechanisms of angles of elevation and traversing angles Check it by rotation of the device around the horizontal and vertical axes with the use of handles 6 Figure 1 The rotation must...

Страница 11: ...torage It is not permitted to store the device on the floor near stoves at the windows The premises where the device is stored must be dry and heated The air temperature in the premises must be not lo...

Страница 12: ...tored silica gel must not be exposed to the open air for more than two minutes to avoid saturation of silica gel with moisture from the surroundings Silica gel can be restored unlimitedly in doing so...

Отзывы: