background image

 

 

3  The  level  bubble  is  not 
visible or is extended and 
exceeds  the  bounds  of 
the middle lines of the vial 
 

The  level  is  out  of 
order 
 

Replace  it  with  a  fit 
one 
 

4 The lamp fails to light 
 

The lamp is burnt 
 

Replace  it  with  that  in 
good order 
 

 
 
 
 
 
 

9  RULES  OF  STORAGE 

 
After operation  with the device one should clean the  outer surfaces of the optical pieces against dust 

and moisture, put caps on the eyepieces and put cover on the device or place the device in the packing 
case. 

All  the  places  of  the  device  which  are  no  bar  to  penetration  of  moisture  and  dust  inside  are  filled  up 

with  special  watertight  putty,  therefore  it  should  be  seen  that  this  putty  is  always  in  good  order.  The 
unpainted parts of the device - the tripod pin, the headrest pin and so on  - should be coated with a thin 
layer of grease to avoid   corrosion. 

The mechanical parts of the packing cases should be slightly greased to avoid rusting. All accessories 

and spare parts are to be put in their mortizes in the cases when in storage. 

It is not permitted to store the device on the floor, near stoves, at the windows. 
The premises where the device is stored must be dry and heated. 
The air temperature in the premises must be not lower than 5 °C and relative humidity at a temperature 

of (25±10) °C must not exceed 70 %. 

The tripod is stored together with the device complete set. 
The  alkaline  accumulators  are  stored  in  compliance  with  the  maintenance  instructions  on 

accumulators. 

 

10  ACCEPTANCE  CERTIFICATE 

 
Binocular observation device  PNB-3 (PNB-3-1), serial No.               ,  is  in  compliance  with  technical 

requirements and found fit for service. 

 
Date of issue ____________________________  
 
Signatures ______________________________ 
 

 

 

(stamp) 

 
 
 
Federation State Unitary Enterprise 
Production Amalgamation “Novosibirsk Instrument-Making Plant” 
179/2, D.Kovalchuk, 
Novosibirsk, 630049 
Russian    
 
 
Supplement 1 
 

RESTORATION  OF  ABSORBING  CAPACITY  OF  SILICA GEL 

 
For  restoration  of  absorbing  capacity  of  silica  gel  it  is  necessary  to  screw  out  the  cap  from  the 

desiccator, pour silica gel in a clean metal vessel which is put on the heat source (an electric stove, coals 
of a bonfire and so on). 

The direct contact of silica gel with the flame is to be avoided. 

Содержание PNB-3

Страница 1: ...Federal State Unitary Enterprise Production Amalgamation Novosibirsk Instrument Making Plant BINOCULAR OBSERVATION DEVICE PNB 3 SOKOL Service manual AL3 803 100 RE...

Страница 2: ...servation and determination of angular coordinates of objects observed from the stationary and temporary observation posts by day and night by the light of searchlights As distinct from PNB 3 1 device...

Страница 3: ...old 10 field of view deg 7 resolution in the centre of the field of view 5 range of measuring the angles deg elevation from minus 18 to 84 the traversing angles 360 Tell tale pipe magnification fold 8...

Страница 4: ...15 9 of the tripod 6 2 of the system of illumination 0 44 of the accumulator in the housing 2 of the device packed 53 12 50 3 COMPLETE SET Table 2 Name Value PNB 3 PNB 3 1 Observer s binoculars 1 1 T...

Страница 5: ...lar observation device PNB 3 Service manual 1 1 1 Nickel cadmium accumulators of NK 13 type Maintenance instructions 1 4 SAFETY PRECAUTIONS The device should be reliably secured at the seat of the tri...

Страница 6: ...sight in the vertical plane are read in the range from minus 18 3 00 to plus 84 14 00 from scale 7 and by the nonius secured rigidly in the bracket Readings are taken from the scale through the port...

Страница 7: ...optical pieces of the device Mount the headrest on the device Fix the lamp holders at the seats of the eyepieces of the binoculars and tell tale pipe In operation at night connect the plug coupling t...

Страница 8: ...e value of correction in divisions of the deflection which is added to the result obtained before Example It is required to take readings from the scale of the horizontal limb in compliance with figur...

Страница 9: ...e completeness in compliance with the list of complete set Check it by visual inspection The complete set must be fully available 2 The outer appearance of the device and its parts reliability of secu...

Страница 10: ...peration of the mechanisms of angles of elevation and traversing angles Check it by rotation of the device around the horizontal and vertical axes with the use of handles 6 Figure 1 The rotation must...

Страница 11: ...torage It is not permitted to store the device on the floor near stoves at the windows The premises where the device is stored must be dry and heated The air temperature in the premises must be not lo...

Страница 12: ...tored silica gel must not be exposed to the open air for more than two minutes to avoid saturation of silica gel with moisture from the surroundings Silica gel can be restored unlimitedly in doing so...

Отзывы: