Technical data

Electric motor

:

Connection voltage:

See identification plate

Power consumption:

800 W

Rotational speed:

max. 10000 min-1

Mode of operation:

S 3; 25 % 100 s

Protection class:

1

Mode of protection:

IP - 44

Radio interference:

As per VDE 0875

Power connection:

Cable, 5 m long, with a three-phase safety

pedal switch and earthing contact-type plug

Hydraulics

:

Hydraulic connection:

Quick-action coupling plug with back-pressure valve

Operating pressure:

150 bars max.

Delivery capacity:

at n = 1000 min

-1

:

HA 1 = 0.45 l/min
HA 2 = 0,9 l/min

Dimensions:

HA 1 ES:

H = 470 mm;

B = 250 mm;

L = 280 mm

HA 2:

H = 470 mm; 

B = 280 mm;

L = 460 mm

Weight incl. oil:

HA 1 ES:

18 kg

HA 2:

34 kg

Hydraulic oil:

Oil filled in at works:

ISO VG 10 DIN 51519
(suitable for external temperatures from-5 to +35 °C)

Oil usable:

Oil in viscosity class:
ISO VG DIN 51519 from 10 to 46
(viscosity in CSt 7.4 - 30 at 50 °C)

Oil for temperatures < - 5 °C:

ISO VG 5 DIN 51519

Содержание HA1ES

Страница 1: ...31070 B03eng 0496 OPERATING INSTRUCTIONS FOR HYDRAULIC DRIVE SYSTEMS HA1ES HA2...

Страница 2: ...Page CE Conformity Declaration Safety regulations Technical data 1 Range of application 2 Construction 2 Connecting system tools 3 Three phase safety pedal switch 4 Operation 5 Maintenance 6 Appendix...

Страница 3: ...pe plug Hydraulics Hydraulic connection Quick action coupling plug with back pressure valve Operating pressure 150 bars max Delivery capacity at n 1000 min 1 HA 1 0 45 l min HA 2 0 9 l min Dimensions...

Страница 4: ...0740 for electric tools An oil filling screw with breather valve 3 and an oil gauge 4 are mounted on the oil tank cover Oil gauge 4 The gauge stick of the oil gauge must be between the two markings If...

Страница 5: ...unt of oil will remain between the back pressure valves of the coupling Handle the hydraulic hose with care Bends at the connection points will lead to premature breakdown When coupling up make sure t...

Страница 6: ...as far as detectable stop of pressure point System tool ON 3 Pedal actuated beyond pressure point EMERGENCY OFF Pedal switch locked Note When EMERGENCY OFF is actuated The hydraulic control unit is sw...

Страница 7: ...il and is damagedas a result Actuate the manual key or pedal switch and hold it down Note When the manual or pedal switch is released the piston of the system tool will return immediately The piston o...

Страница 8: ...s Hydraulic oil See Technical Data Oil filter The oil filter is the suction strainer with a mesh width of 0 06 mm Unscrew the oil filling screw with the air relief valve 3 on the oil tank cover Draw o...

Страница 9: ...essary Every 6 months Have an inspection complying with VBG 4 and DIN VDE 701 section 1 and section 260 for electric devices of the protection class 1 carried out by a qualified technician an authoriz...