background image

7

31070\B03eng

0496

Visual and electrical inspection

Regularly:

Check mains cable including plug and extension cord with plug connectors for
visible damage and have repaired, if necessary.

Every 6 months:

Have an inspection complying with VBG 4 and DIN VDE 701, section 1 and 
section 260, for electric devices of the protection class 1 carried out by a 
qualified technician, an authorized workshop or Novopress Neuss.

Hydraulic drive unit H A 1 E S

Legend:

1  =  Control line

2  =  Hydraulic hose

3  =  Air-relief valve

4  =  Oil gauge

5  =  Plug-in connector

6  =  Pushbutton

7  =  Pedal switch

Содержание HA1ES

Страница 1: ...31070 B03eng 0496 OPERATING INSTRUCTIONS FOR HYDRAULIC DRIVE SYSTEMS HA1ES HA2...

Страница 2: ...Page CE Conformity Declaration Safety regulations Technical data 1 Range of application 2 Construction 2 Connecting system tools 3 Three phase safety pedal switch 4 Operation 5 Maintenance 6 Appendix...

Страница 3: ...pe plug Hydraulics Hydraulic connection Quick action coupling plug with back pressure valve Operating pressure 150 bars max Delivery capacity at n 1000 min 1 HA 1 0 45 l min HA 2 0 9 l min Dimensions...

Страница 4: ...0740 for electric tools An oil filling screw with breather valve 3 and an oil gauge 4 are mounted on the oil tank cover Oil gauge 4 The gauge stick of the oil gauge must be between the two markings If...

Страница 5: ...unt of oil will remain between the back pressure valves of the coupling Handle the hydraulic hose with care Bends at the connection points will lead to premature breakdown When coupling up make sure t...

Страница 6: ...as far as detectable stop of pressure point System tool ON 3 Pedal actuated beyond pressure point EMERGENCY OFF Pedal switch locked Note When EMERGENCY OFF is actuated The hydraulic control unit is sw...

Страница 7: ...il and is damagedas a result Actuate the manual key or pedal switch and hold it down Note When the manual or pedal switch is released the piston of the system tool will return immediately The piston o...

Страница 8: ...s Hydraulic oil See Technical Data Oil filter The oil filter is the suction strainer with a mesh width of 0 06 mm Unscrew the oil filling screw with the air relief valve 3 on the oil tank cover Draw o...

Страница 9: ...essary Every 6 months Have an inspection complying with VBG 4 and DIN VDE 701 section 1 and section 260 for electric devices of the protection class 1 carried out by a qualified technician an authoriz...

Страница 10: ...Repairs Service Scharnhorststra e 1 PO Box 101163 D 41460 Neuss D 41411 Neuss Telex 8 518 015 Tel 02131 2880 Federal Republic of Germany Telefax 02131 28855...

Отзывы: