Fault diagnosis
Fault
Condition
Diagnosis/Remedy
__________________________________________________________________________________________________________________
E05
Gate neither opens nor closes
Safety circuit at J3 is interrupted.
Check the slack rope switch; wicket door not closed.
__________________________________________________________________________________________________________________
E06
cables. In the case of
Gate reverses/does not close
Edge safety device has tripped; check the edge safety device and is
[35] pressed.
an AK edge safety device keep the programming button in menu
_________________________________________________________________________________________________________
E07
Gate reverses/does not close
The light barrier has tripped.
__________________________________________________________________________________________________________________
E08
Gate neither opens nor closes
The thermo-contact for the drive has tripped; let the drive cool down.
Emergency drive release; unlock the drive again.
__________________________________________________________________________________________________________________
E09
[30] / [31].
Gate neither opens nor closes
No end position taught-in; tech-in the gate end positions in menus
__________________________________________________________________________________________________________________
E10
the gate completely,
Teach-in of the light barrier position
Position of the light barrier in the frame not taught in. Open and close
adjust the light barrier.
__________________________________________________________________________________________________________________
E51
check it.
Gate does not open
Permanent start of the cover button OPEN, button might be jammed,
__________________________________________________________________________________________________________________
E52
might not have
Gate neither opens nor closes
Cover button STOP has been pressed. Button might be jammed. Cable
been plugged in.
__________________________________________________________________________________________________________________
E53
.
Gate does not close
Permanent start of the cover button CLOSE, button might be jammed
__________________________________________________________________________________________________________________
E54
.
Gate does not open
Permanent start J1.3 > button OPEN, button might be jammed, check it
__________________________________________________________________________________________________________________
E55
Gate neither opens nor closes
External STOP button J1.2 has been pressed or bridge is missing. Check
connecting cable to the external command transmitter.
__________________________________________________________________________________________________________________
E56
Gate does not close
Permanent start J1.4 > button CLOSE, button might be jammed, check it
__________________________________________________________________________________________________________________
E5E
Gate only closes in the dead-man mode
Service cycle has expired; have the system serviced.
Subject to modifications
Fault
Condition
Diagnosis/Remedy
__________________________________________________________________________________________________________________
F2
.
No response
Fault during the self-test; switch control off/on
__________________________________________________________________________________________________________________
F3
.
No response
Fault during the self-test; switch control off/on
__________________________________________________________________________________________________________________
F4
.
No response
Fault during the self-test; switch control off/on
__________________________________________________________________________________________________________________
F5
.
No response
Fault during the self-test; switch control off/on
__________________________________________________________________________________________________________________
F6
.
No response
Fault during the self-test; switch control off/on
__________________________________________________________________________________________________________________
F10
.
Gate stops after the start command
Fault in the control electronics; switch control off/on
__________________________________________________________________________________________________________________
F19
Gate only closes in the dead-man mode
Test of the DW edge safety device failed; check the edge safety device.
__________________________________________________________________________________________________________________
F20
.
Gate only closes in the dead-man mode
Test of the light barrier failed; check the light barrier
__________________________________________________________________________________________________________________
F21
Brief interruption of operation
Runtime limitation of the gate; let the drive cool down for approx. 20 min
__________________________________________________________________________________________________________________
F24
.
No response to the start command
No connection with the DES; check both power supply cable and DES
__________________________________________________________________________________________________________________
F27
.
in menus 33 &34
Gate does not reach end position; gate
Springs overstressed. Check the door balance. Adjust the end positions
neither opens nor closes
Drive is blocked. Check the gate's mechanical system,the mains and motor phases.
__________________________________________________________________________________________________________________
F28
No response to the start command
Fault in the power supply; check the connection with the mains.
Check whether the 24-V consumers are short-circuited.
__________________________________________________________________________________________________________________
F29
adjust them.
Motor rotates in the wrong direction
Mains phases have been transposed: correct the mains phases or re
Gate stops after the start command
Gate drive is too fast, the overrun of the drive is too high.
Gate stops after reversing
__________________________________________________________________________________________________________________
F30
Gate only closes in the dead-man mode
Return of the pulse into the dead-man mode. Edge safety device or light barrier has tripped.
Opening force limitation has been activated. The motor's power-on time has been exceeded.
__________________________________________________________________________________________________________________
F33
Gate stops during opening
The opening force limitation has tripped. Gate can only be closed in the dead-man mode.
Rectify the gates sluggishness or blockage. Check the springs. Eliminate the cause of
exceeding the force limitation and open and close the gate thereafter.
__________________________________________________________________________________________________________________
F34
Gate neither opens nor closes
The motor's power-on time (menu 49) has been exceeded. Wait a while and let the motor cool down.