04/13 Rev. 1.12-02
USER / SERVICE MANUAL
Mounting/Setup
LA-TO / LA-TO XL
Settings
20
Position of the pressure plate
The following sections only apply to units where a
LA -TO is mounted onto an ALX 92x. Furthermore, only
one variant of the vacuum plate is shown. However, the
settings described here apply analogously to units
where a LA -TO is mounted onto an ALS 20x, ALS 30x
or an ALX 73x together with any other type of vacuum
plate.
Tools
•
4mm hex socket driver
•
Flat wrenches: sizes 10/13/17
•
Calliper gauge
•
Screw drivers: small, medium
Adjusting the lateral position
The lateral position of the vacuum plate must be set
such that labels can be pushed onto the centre of the
vacuum plate. If this is not the case, the lateral position
of the vacuum plate can be adjusted as follows:
1. Unplug the compressed air line.
2. Remove the two Allen bolts [25A].
3. Push the vacuum plate so that the labels are trans-
ferred centrally.
4. Fasten the vacuum plate in place using the Allen
WARNING!
Injury hazard by unintentionally triggered
applicator.
Unplug the compressed air line before
starting the adjustment.
[25] Adjusting the lateral position.