3. I/O Connectors

 

 

 

   3.1 Power

 

 

3.1.1

    Connection from a Surge Suppressor outlet to the SF-100e is done using the 

AC adapter that came with the SF-100e. The SF-100e requires 5V DC at an  

            average of .7A. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

-     Input: AC 100V-240V 50/60Hz @ 0.3A Max

 

-     Output: 5V @ 2A Max 

 
 
 
 
 
 
 
 
 
 
 
 

•    

The AC adapter shipped with the SF-100e is high efficiency, super cool 
and unusually versatile. This power adapter can be adjusted to plug  

      normally into a wall socket and has a much lower profile than a regular 

AC adapter.

 

 

•    

The AC adapter can also be adjusted to the upright position, allowing it to 
be plugged into a power strip and only take up one outlet. Standard AC 
adapters can take up two and sometimes three outlets in a power strip. 

 

           IMPORTANT: Use of any unauthorized AC adapter will void your warranty.

 

 
 

Содержание SF-100e

Страница 1: ...1 Noventri Eco Series User Guide SF 100E 0160 01 REV 03 SF 100e INSTALLATION USER GUIDE ...

Страница 2: ... of Contents 1 Overview 3 2 Getting Started 3 3 I O Connectors 4 3 1 Power 4 3 2 VGA DVI HDMI Out 5 3 3 Ethernet Port 5 3 4 USB Port 6 3 5 RS 232 Port 6 4 Installation 7 5 Network Usage 8 6 Stand Alone Usage Sneakernet 12 7 Factory Defaults 12 8 Specifications 13 ...

Страница 3: ...ied over and inserted into the SF 100e 1 5 When used as part of an Ethernet network the SF 100e plays content that is created in the Suite software and is sent to the Player using the Server software 1 6 The SF 100e when used over the Internet plays content that is created in the Suite software and is sent to the Player over the Internet using the Server software 2 Getting Started 2 1 When you rec...

Страница 4: ...The AC adapter shipped with the SF 100e is high efficiency super cool and unusually versatile This power adapter can be adjusted to plug normally into a wall socket and has a much lower profile than a regular AC adapter The AC adapter can also be adjusted to the upright position allowing it to be plugged into a power strip and only take up one outlet Standard AC adapters can take up two and someti...

Страница 5: ... your local network is made through the Ethernet port If you plan on using your SF 100e as a networked Player you will need an Ethernet Cat 5 cable 3 3 2 By default the SF 100e is set to get an IP Address using DHCP If the player cannot get one assigned it will then use 192 168 0 190 as the default IP Address You can also make arrangements with Noventri to customize your SF 100e player IP Address ...

Страница 6: ...atically update the player and content from a new project IMPORTANT The USB Drive must be plugged in at all times If the drive is removed the player will not be able to continue playing as all the content is stored on it 3 5 RS 232 Port 3 5 1 The RS 232 port is currently not used but will soon have the ability to send commands such as power on off adjust volume or change source input to monitors t...

Страница 7: ...our local network 4 3 1 If you are installing multiple SF 100e players to your network and they come up with the default IP Address 192 168 0 190 you must connect only one player to the network at a time and change its IP Address to another one before connect ing the next SF 100e player See the Network Usage section of this manual 4 4 If you plan on using your SF 100e as a stand alone Sneakernet p...

Страница 8: ...e used Note Make sure that another device on the network is not using the same player s default 192 168 0 190 IP Address 5 4 When the SF 100e boots up it will get an IP Address DHCP or the default IP Address if one is not found The Noventri Splash Screen will be displayed with the IP Address it will be using and the Resolution the player is set to This is a good time to write down the IP Address f...

Страница 9: ...ou are unable to log in to your SF 100e you can reset it back to the default See Factory Defaults section of this Manual 5 8 Once you are logged on to the SF 100e you will see the following Configuration screen showing your current configuration Important Since you are logged into the SF 100e via its IP Address any changes made to the IP Address such as DHCP ENABLE or a new STATIC IP Address may c...

Страница 10: ...100e the player can be reset back to factory defaults see Factory Defaults section of this Manual 5 8 2 IP ADDRESS You can set a static IP ADDRESS for the SF 100e If the IP ADDRESS is changed be sure you have the correct NETMASK and GATEWAY filled in for your network For the new IP Address to be set you will have to apply these changes by clicking the SUBMIT button This will take a moment If you a...

Страница 11: ...identify each SF 100e when it was built and which batch it came from 5 8 10 NEW PASSWORD If you would like to change the default password of the SF 100e enter the New Password here Note If you are unable to log in to your SF 100e you can reset it back to the default See Factory Defaults section of this Manual 5 8 11 RE ENTER PASSWORD If you entered a New Password enter it again here for verificati...

Страница 12: ...plug it into the USB port of the SF 100e 6 6 The SF 100e will read the files on the USB Drive and automatically start playing the Project with sequences of images displayed on the monitor Note If the SF 100e requires a firmware update publishing using Sneakernet will automatically update the player first before the Project begins to play 7 Factory Defaults 7 1 If you need to reset your settings to...

Страница 13: ...5 35 x 4 4 x 1 1 Weight 0 5 lbs Heavy duty all aluminum chassis Sneakernet USB Port accepts content updates if network is not available Output Options VGA DVI HDMI Output Resolutions 640 X 480 800 X 600 1024 X 768 1280 X 720 1280 X 768 1280 X 1024 1360 X 768 1366X 768 1440 X 900 1600 X1200 1920 X 1080 and 1920 X 1200 as well as custom resolutions upon request Solid State Design The SF 100e is desi...

Страница 14: ...i SF 100e and electrical accessories such as signal cables or power cords When you need to dispose of your Noventri products please follow the guidance of your local authority ask the Noventri local distributor or contact Noventri directly for instructions Outside the European Union Please contact your local authority so as to comply with the correct disposal method NOVENTRI 1 800 359 1858 www nov...