Configuration:
In order to use these features, we must perform some configuration of the system to reflect our desires.
The order of events to configure the system is as follows:
AT\APROG,NRM6812
*enter program mode
AT#ADV=4.0
*assumes that the voltage input currently is 4.0 volts
AT#ADV=3.5,3.3
* configures the warning and shutdown thresholds
AT#ADH=0.10
* configures the hysteresis to be 3.6V-3.5V or 0.10V
AT#ADN=5,5,5
* configures the hysteresis counts to be 5 readings
AT#ADM=1
* enables the low voltage monitor
ATIO2=10
* enables the Low Battery Indication signal on GPIO2.
AT&W
* saves all settings.
This completes all configuration functions associated with the desired power monitoring system that we
defined. The system will now perform the following monitoring:
If voltage is >= 3.5V, no indications
If voltage is 3.3V <= v <= 3.5 for 5 counts, low battery indication is given and LED lights
If voltage rises above 3.6V for 5 counts then, low battery indication is removed and LED turns off
If voltage falls below 3.3V, unit powers off.
Validity:
This command is valid for AT Command mode only.
Once the monitoring functions have been enabled, the shutdown functions will operate. However, the
signals associated with the warnings will only appear on the interface if the Programmable GPIO pins
have been configured to report the associated signals.
Other Considerations:
The voltage measurement is also available through MSCI commands.
Related Topics:
General Purpose IO, Program Mode, Save Profile command