N O V A T E L W I R E L E S S T E C H N O L O G I E S L T D .
2 3
A T C o m m a n d S p e c i f i c a t i o n - E x p e d i t e a n d M e r l i n
W i r e l e s s I P M o d e m s
c = complete scan period in seconds. This is the time
that the modem will be awake once in each cycle count
sleep cycles. It is intended to be long enough for the
modem to register on the network if a channel is
available on either side; that is, time to completely search
the cellular environment for a channel to register on.
n = cycle counts in units. One waking interval in “cycle
count” wakeups will be a complete scan. All other
waking intervals will be a brief scan.
Validity:
Changes must be entered in program mode.
Other Considerations:
Related Topic:
Sleep Mode