background image

7

 ~

 

NOVATEK-ELECTRO

                                                                                                          ЕТ-485    

 

                                                                                                                                   

 

WARNING! CONTINUOUS ACTIVATION OR FLASHING OF “ERROR” INDICATOR IN THE ABSENCE 
OF CONNECTIONS TO THE UNIT INDICATES UNIT MALFUNCTION. 

Etherne

t network connection pending. The network connection is established, if “

Ethernet

” indicator 

becomes activated. Flashing of “

Ethernet

” indicator stands for transmitting data over the network. 

 

 

 

Figure 4

 

– Unit connection diagram 

 

6.2. OPERATING 

ЕТ-485 OVER THE HTTP PROTOCOL 

ET-485 waits for a connection to an Ethernet network using the HTTP protocol on port 80. PC connection can 

be established using the WEB-browser.  

When  a  client  connects  to  port  80,  the  unit  starts  expecting  requests  for  HTML-pages.  These  requests  may 

contain certain parameters. In case of a valid request, those parameters are processed and the client receives the 
text of a selected HTML-page. In case of a request without an indication of certain page, the client is returned to the 
title page. When the page is transferred, the unit deactivates the client and awaits for further connection. 

 

6.3. OPERATING 

ЕТ-485 OVER THE MODBUS TCP PROTOCOL 

While operating, the ET-485 waits for a connection to an Ethernet network using the Modbus TCP protocol 

on port 502. The connection port for Modbus TCP can be changed by the user. PC connection can be established 
using  any  software 

–  Modbus  TCP  of  the  clients.  Client  software  for  ОС Windows  can  be  downloaded  from  the 

manufacturer's web-site (http://novatek-electro.com/programmnoe_obespechenie.html). 

When a request for client connection to the Modbus TCP port is received, the unit starts verifying the client's IP-

address  (if  connection  filtering  over  IP  is  activated).  If  this  address  does  not  correspond  with  the  preset  value,  the 
connection  is  rejected.  Otherwise,  the  unit  starts  checking  the  list  of  available  connections.  In  case  of  no  available 
connections, the unit (depending on the configuration) can connect a new client instead of the previously connected 
one (if no activity of the client was registered over a set period of time, or if the connection is maintained longer than 
prescribed).  

When connecting a client to Modbus TCP port, the unit adds it to the internal list of served clients (but not 

exceeding the number of clients, specified in the technical characteristics). 

When connection of the client is established, the unit awaits a Modbus-query from the client. In the RS-485 slave 

mode, the device also accepts RS-485 queries from the master device of Modbus network. 

When  the  query  from  the  client  has  been  received,  the  unit  analyzes  the  query  and,  depending  on  the 

requested  function  code  and  the  current  rights  of  the  client,  either  processes  or  blocks  it.  When  the  query  is 
blocked,  ET-485  can  generate  and  transfer  the  client-specified  Modbus  exception  code  (default 

–  code  1)  to  the 

client. The rights of the client, depending on the settings, are determined according to its IP address (the Modbus 
network master IP address is considered to be 127.0.0.1) and input passwords. 

If the query is addressed to 

ЕТ-485, the unit does not redirect the query, processes it and transfers the answer 

to the client. 

In the RS-485 master mode, queries to other devices are redirected to Modbus network and an answer form 

Modbus network is awaited 

– herewith the 

«RS-485»

 indicator will start to glow. If the data have been received or 

the standby time has run out, the 

«RS-485»

 indicator will go out. 

Содержание ET-485

Страница 1: ...perating conditions and wait at least 2 hours before connecting it to the electricity mains Do not use abrasives or organic compounds alcohol gasoline solvents etc for cleaning DO NOT OPEN AND REPAIR...

Страница 2: ...6 6 2 Operating 485 over the HTTP protocol 7 6 3 Operating 485 over the Modbus TCP protocol 7 6 4 The operation of ET 485 in the mode of active connection to the client 8 7 SETTINGS 8 7 1 General info...

Страница 3: ...onnecting side acts as a server Twisted pair is a pair of insulated conductors inside the cable which are twisted together in order to reduce the distortion of the transmitted signal Indicator is a LE...

Страница 4: ...nit to the mains sec no more than 1 Utilized current in case of 220 V mA at most 10 Weight kg at most 0 200 Dimensions mm 95 52 67 Unit purpose Communication equipment Nominal operation condition cont...

Страница 5: ...g while data exchange over the Ethernet network Figure 2 Front panel of ET 485 3 2 FUNCTIONING Simplified structural diagram of the unit is provided in Figure 3 32 digit RISC processor with ARM archit...

Страница 6: ...CEDURE FOR 485 Suggested maintenance interval every six month The maintenance procedure includes visual inspection to verify the connection of cables to the 485 terminals as well as the absence of fra...

Страница 7: ...ddress if connection filtering over IP is activated If this address does not correspond with the preset value the connection is rejected Otherwise the unit starts checking the list of available connec...

Страница 8: ...NFIGURATION MAY RESULT IN BLOCKING OR OBSTRUCTION WHILE TRYING TO REACH THE UNIT OVER THE NETWORK In this case all parameters should be factory reset see Section 3 2 7 2 PARAMETERS OF 485 A collection...

Страница 9: ...s Mode more detailed see register 141 0 User mode 1 Configuration mode 121 Current IP address IP address of the unit in Ethernet network 122 125 Current MAC address MAC address to authenticate the uni...

Страница 10: ...1 the connected client has the permit for setting ET 485 similar to register 121 Bit 8 0 the client is not the main client 1 the client is the main client Bit 9 1 the client has the right for connecti...

Страница 11: ...ed 1 setting parameters via Modbus interface or WEB interface is only allowed from the IP address of the main client 526 Enable the IP connections filter over Modbus TCP 0 1 0 0 Modbus TCP connections...

Страница 12: ...sponse has not been received within the given time as indicated for the reception of res ponse Waiting time shall not be less then time required for transmission of a single character depending on the...

Страница 13: ...additional client having IP address 127 0 0 1 587 Enable the Modbus TCP remote server query redirection mode 0 1 0 0 queries are not sent to remote server 1 queries are additionally sent to Modbus TC...

Страница 14: ...ent 0 automatic sending is not accomplished 1 after active connection to the client the unit once sends 1000 1010 registers contents in the form of Modbus response without client query response 1000 1...

Страница 15: ...ress IP address DHCP settings are modified and saved the browser may not load the page after the restart of the unit by pressing the Restart button This can happen as the browser continues to reply ov...

Страница 16: ...se 9 5 The manufacturer s warranty does not apply to compensation for direct or indirect damages loss or injury associated with transporting the unit to the place of purchase or to the manufacturer 9...

Страница 17: ...not necessary for communication between units in a subnet and is only used to connect units of one subnet to units of other networks Factory addressing settings for ET 485 Interface Converter are lis...

Страница 18: ...roperties Figure 2 TCP IP properties window in Windows OS window in Windows OS 3 SWITCHING TO INTERNET WARNING The user is strongly recommended to connect the unit to Internet under the supervision of...

Страница 19: ...ET 485 IP address filters for recording and or reading can be enabled to provide to a single client the permit to request via Modbus protocol such function codes which are not reading functions unit s...

Страница 20: ...direction of queries If the unit whereto the queries are redirected is set to such redirection that the query will be transferred to its initial sender the queries will be transferred nonstop which wi...

Страница 21: ...w unit can be specified as the main client It allows increasing the number of RS 485 connected devices and simultaneously connected Modbus TCP clients by 10 for every additional ET 485 unit Each of th...

Страница 22: ...g receiving alert messages about incidents via SMS or E Mail Overvis system maintains ACC mode used in ET 485 acting as a data collection server of many simultaneously connected units and providing ac...

Страница 23: ...etc b client uses unique MAC address of the unit for its identification In order to provide the access for the user the unique activation code is given to each unit herewith Modbus write protection m...

Страница 24: ...ode Symbol 32 64 96 33 65 A 97 A 34 66 B 98 B 35 67 C 99 C 36 68 D 100 D 37 69 E 101 E 38 70 F 102 f 39 71 G 103 g 40 72 H 104 h 41 73 I 105 i 42 74 J 106 j 43 75 K 107 k 44 76 L 108 l 45 77 M 109 m 4...

Страница 25: ...AC110 61F GPN V50 AC110 70177 1011 F03 03 HAS B F03 03 HAS C F03 31 81513201 81513535 81550401 FT1A C12RA W 88981106 H2CAC24A R88A CAGA005S R88A CRGB003CR E R88ARR080100S R88A TK01K DCN1 1 DTB4896VRE...

Отзывы: