![NovaTec NovaWheel NW Series Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/novatec/novawheel-nw-series/novawheel-nw-series_instruction-manual_1711076019.webp)
NovaWheel Instruction Manual
19
Document#: IM NW400-2000_10-07-08
NW Series NovaWheel Dryer
INSTRUCTION MANUAL
The Password Setup Screen has listed 6
other screens with a space for passwords
and a selector pad to either enable or
disable the password. Any 5-digit number
may be set as a password. To enable the
password and protect the screen, enter the
password and depress the associated pad.
The pad will show “Enabled” and the
protection will become active after leaving
this screen.
On this screen, the alarm value for the system
dew point is set. It also has the settings for the
Moisture Manager. If the Moisture Manager is
turned on the reactivation temperature will be
decreased by 5 degrees per revolution of the
desiccant cassette. It will use the moisture
manager set point as a target and adjust the
system to stay between the high and low
alarm values.
The Features Menu holds the set points for
the Second Set Point Remote Delay,
Second Set Point Sleep Delay, all material
handling, and the Water Saver and Water
Saver Alarm values.