background image

NovaLynx Corporation 
 

 

255-110x-B 

Page 4 

March 2021 

 

1

 

FORWARD

 

 

Thank you for purchasing NovaLynx products. NovaLynx has been designing and manufacturing 
weather instruments since 1988. NovaLynx represents several well-known brands of quality 
manufacturers, including Gill Instruments, RM Young, Kipp & Zonen, and Vaisala. It is our hope that our 
products will meet all your monitoring requirements. 

2

 

INTRODUCTION 

 
The 

255-110x-B Evaporation Gauge Reader 

is a portable display for the NovaLynx 255-100 Analog 

Output Evaporation Gauge. The reader is calibrated in inches or millimeters, depending on the model 
chosen. Readings from the display indicate 

relative

 depth of water in the gauge. The difference 

between readings on successive days indicates the amount of evaporation.  

 

The reader may be used during installation of the evaporation gauge and for checking the operation of 
the evaporation gauge during regular maintenance.

 

The large LCD display is visible through the clear 

protective cover even in bright sunlight.  

The NovaLynx 255-110x-B Reader is pre-calibrated using a generic slope with zero offset. Since the 
float in the 255-100 Evaporation Gauge does not rise until a certain amount of water is present, the 
display will not correspond to the actual depth of the water in the pan. However, since evaporation is a 

relative

 quantity (the difference in level between two points in time), the offset is not important, as 

long as the float is not resting on the bottom. 

It is possible to calibrate the reader to a specific evaporation gauge using a two-point method, which 
will adjust the slope and offset so that the readings match (within reason) the depth of water in the 
evaporation pan. NovaLynx 195-BHW-KIT includes software and a USB cable for programming the 
slope and offset. Instructions for programming the display are available in the NovaLynx 255-704-B 
Evaporation Logger User Manual, available on our website at www.novalynx.com. 

 

Raw

Scaled

Units:

Volts

Inches

Value 1:

0.00000

0.00000

Value 2:

2.50000

9.44400

Raw

Scaled

Units:

Volts

millimeters

Value 1:

0.00000

0.00000

Value 2:

2.50000

239.89000

255-110-B Generic Calibration

255-110M-B Generic Calibration

Содержание 255-110-B Series

Страница 1: ...M 20210324 255 110x B User Manual 255 110 B Evaporation Gauge Reader inches 255 110M B Evaporation Gauge Reader millimeters Evaporation Gauge Reader Phone 530 823 7185 Email nova novalynx com Website...

Страница 2: ...items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with the packaging Please write the RA on the outside of...

Страница 3: ...ARD 4 2 INTRODUCTION 4 3 SPECIFICATIONS 5 4 CONNECTIONS 5 5 APPLICATION Evaporation Monitoring 6 6 APPLICATION Evaporation Logging 7 7 APPLICATION Evaporation Gauge Chain Installation 7 8 APPLICATION...

Страница 4: ...e cover even in bright sunlight The NovaLynx 255 110x B Reader is pre calibrated using a generic slope with zero offset Since the float in the 255 100 Evaporation Gauge does not rise until a certain a...

Страница 5: ...APORATION GAUGE RED Vreg WHITE Signal BLACK Gnd 1 2 3 Counter weight Float 255 110x B EVAPORATION GAUGE READER Screw Terminals Water DWG 890 0092 01 CAUTION To avoid damage to the display connect the...

Страница 6: ...are discussed in their respective user manuals available at www novalynx com Each day or other regular interval connect the reader to the evaporation gauge following the instructions Section 4 Record...

Страница 7: ...sistance is infinite and the readings from the gauge would be meaningless Chain Installation Using the Reader 1 Make sure the gauge is empty of water 2 Connect the reader Section 4 3 Turn the sprocket...

Страница 8: ...The back side of the sprocket has similar ridges but none are painted 2 Connect the reader to the evaporation gauge and verify that it responds to small movements of the sprocket Remember the display...

Страница 9: ...to be replaced The measured depth of water and the display will not agree when calibrated to the generic settings because the amount of water required to raise the float is not accounted for This is n...

Страница 10: ...es are being changed FIRST Connect a USB cable from your logger to a computer USB wall charger or USB output battery pack The cable type is USB 2 0 A to Mini B 1 Open the battery door on the back of t...

Отзывы: