Receiving and Unpacking

 

 

Carefully unpack all components and compare to the packing list. Notify NovaLynx Corporation 
immediately concerning any discrepancy. Inspect equipment to detect any damage that may have 
occurred during shipment. In the event of damage, any claim for loss must be filed immediately with 
the carrier by the consignee. Damages to equipment sent via Parcel Post or UPS require the consignee 
to contact NovaLynx Corporation for instructions. 

 

Returns

 

 

If equipment is to be returned to the factory for any reason, call NovaLynx between 8:00 a.m. and 4:00 
p.m. Pacific Time to request a Return Authorization Number (RA#). Include with the returned 
equipment a description of the problem and the name, address, and daytime phone number of the 
sender. Carefully pack the equipment to prevent damage or additional damage during the return 
shipment. Call NovaLynx for packing instructions in the case of delicate or sensitive items. If packing 
facilities are not available take the equipment to the nearest Post Office, UPS, or other freight service 
and obtain assistance with the packaging. Please write the RA# on the outside of the box. 

 

Warranty

 

 

NovaLynx Corporation warrants that its products are free from defects in material and workmanship 
under normal use and service for a period of one year from the date of shipment from the factory. 
NovaLynx Corporation's obligations under this warranty are limited to, at NovaLynx's option: (i) 
replacing; or (ii) repairing; any product determined to be defective. In no case shall NovaLynx 
Corporation's liability exceed product's original purchase price. This warranty does not apply to any 
equipment that has been repaired or altered, except by NovaLynx Corporation, or that has been 
subjected to misuse, negligence, or accident. It is expressly agreed that this warranty will be in lieu of 
all warranties of fitness and in lieu of the warranty of merchantability. 

 

Address

 

 

NovaLynx Corporation 
431 Crown Point Circle, Suite 120 
Grass Valley, CA 95945-9531 USA 
Phone: (530) 823-7185 
Email: [email protected] 
Website: www.novalynx.com

 

 

Copyright © 1988-2021 by NovaLynx Corporation 

 

 

Содержание 255-110-B Series

Страница 1: ...M 20210324 255 110x B User Manual 255 110 B Evaporation Gauge Reader inches 255 110M B Evaporation Gauge Reader millimeters Evaporation Gauge Reader Phone 530 823 7185 Email nova novalynx com Website...

Страница 2: ...items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with the packaging Please write the RA on the outside of...

Страница 3: ...ARD 4 2 INTRODUCTION 4 3 SPECIFICATIONS 5 4 CONNECTIONS 5 5 APPLICATION Evaporation Monitoring 6 6 APPLICATION Evaporation Logging 7 7 APPLICATION Evaporation Gauge Chain Installation 7 8 APPLICATION...

Страница 4: ...e cover even in bright sunlight The NovaLynx 255 110x B Reader is pre calibrated using a generic slope with zero offset Since the float in the 255 100 Evaporation Gauge does not rise until a certain a...

Страница 5: ...APORATION GAUGE RED Vreg WHITE Signal BLACK Gnd 1 2 3 Counter weight Float 255 110x B EVAPORATION GAUGE READER Screw Terminals Water DWG 890 0092 01 CAUTION To avoid damage to the display connect the...

Страница 6: ...are discussed in their respective user manuals available at www novalynx com Each day or other regular interval connect the reader to the evaporation gauge following the instructions Section 4 Record...

Страница 7: ...sistance is infinite and the readings from the gauge would be meaningless Chain Installation Using the Reader 1 Make sure the gauge is empty of water 2 Connect the reader Section 4 3 Turn the sprocket...

Страница 8: ...The back side of the sprocket has similar ridges but none are painted 2 Connect the reader to the evaporation gauge and verify that it responds to small movements of the sprocket Remember the display...

Страница 9: ...to be replaced The measured depth of water and the display will not agree when calibrated to the generic settings because the amount of water required to raise the float is not accounted for This is n...

Страница 10: ...es are being changed FIRST Connect a USB cable from your logger to a computer USB wall charger or USB output battery pack The cable type is USB 2 0 A to Mini B 1 Open the battery door on the back of t...

Отзывы: