NovaLynx Corporation
255-110x-B
Page 10
March 2021
9
BATTERY REPLACEMENT
WARNING: Keep all batteries away from small children. Dispose of used batteries properly.
The battery status indicator is located in the upper right corner
of the display screen. Replace the batteries at the beginning of
the season, and as required. Battery life can vary depending on
circumstances from 7 months to a year.
IMPORTANT:
When the batteries are removed all programming is
lost and the display will go blank UNLESS you provide power to
the display while the batteries are being changed.*
FIRST:
Connect a USB cable from your logger to a computer, USB
wall charger, or USB output battery pack. The cable type is USB
2.0 A to Mini-B.
1. Open the battery door on the back of the logger.
2. Remove the old batteries.
3. Insert two new batteries
observing polarity
.
4. Reinsert the battery door and snap it back into place.
Note: A desiccant pack may be inside the logger box. It can be
replaced or re-dried if needed.
*
If the programming is lost, either return the unit to NovaLynx for inspection and reprogramming, or
obtain the software (free download) and re-program the unit. Instructions for programming the display
are detailed in the
NovaLynx 255-704-B Evaporation Logger User Manual
, available on our website at
www.novalynx.com.