background image

NovaLynx Corporation_____________________________________________________________________________ 

 

 

200-WS-23 

Page 5 

Oct 2020 

 

3

 

SPECIFICATIONS  

 

 

4

 

INSTALLATION 

Please refer to the 200-WS-02F or 200-WS-01B anemometer user manual for information on 
installation and maintenance of the anemometer. Pay particular attention to the location of the sensor 
and align the wind vane to North for best results. Route the cable to the location where the transmitter 
unit will be installed. 
 
The transmitter enclosure may be mounted to the same mast as the anemometer, or wall mounted in 
a convenient location. 

200-WS-23:             

4-20 mA = 0-100 mph

200-WS-23-M:       

4-20 mA = 0-50 m/s

200-WS-23-KM:    

4-20 mA = 0-200 kph

200-WS-02F Wind Direction Transmitter

200-WS-23S:

4-20 mA = 0-100 mph

200-WS-23S-M:

4-20 mA = 0-50 m/s

200-WS-23S-KM:

4-20 mA = 0-200 kph

Loop supply voltage range
Connection
Operating temperature range
NEMA enclosure dimensions
Cable to user equipment

Measurement range
Speed Constant
Transducer type
Speed Threshold
Accuracy

Range
Transducer type
Potentiomenter gap
Azimuth accuracy
Threshold
Bearings

Anemometer mount
Anemometer cable (200-WS-02F)
Anemometer cable (200-WS-01B)

General

1.07" dia. (27 mm)
5 conductor, 24 AWG, shielded, 40' (12 m)
2 conductor, 24 AWG, shielded, 40' (12 m)

Potentiometer, 20k ohms, conductive plastic
5 degrees
± 3 degrees
1.2 mph (0.5 m/s)
Bushing

Reed switch
0.8 mph (0.4 m/s)
1 mph or ± 3%

Wind Direction Sensor (200-WS-02F)

0-360 degrees azimuth

200-WS-02F Wind Speed Transmitter

200-WS-01B Wind Speed Only Transmitter

 Transmitter Specifications

4-20 mA = 0-360 degrees

8 to 30 Vdc
Screw terminal 
-58° to +140° F (-50° to + 60° C)
4.7" x 4.7" x 2.25" (120 x 120 x 57 mm)
Not supplied / order separately

Wind Speed Sensor (200-WS-02F & 200-WS-01B)

0-112 mph (0-50 m/s)

1.25 mph = 1 Hz (0.5588 m/s = 1 Hz)

Содержание 200-WS-23

Страница 1: ...DOC 200 WS 23 UM 20201012 200 WS 23 User Manual Current Loop Wind Sensor 200 WS 23 Wind Speed Direction 200 WS 23S Wind Speed Only Phone 530 823 7185 Email nova novalynx com Website www novalynx com...

Страница 2: ...in the case of delicate or sensitive items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with the packaging P...

Страница 3: ...CONTENTS 1 FORWARD 4 2 INTRODUCTION 4 3 SPECIFICATIONS 5 4 INSTALLATION 5 5 CONNECTIONS 6 6 CALIBRATION 7 APPENDIX A Wind Speed and Direction Wire Diagram 8 APPENDIX B Wind Speed Only Wire Diagram 9 2...

Страница 4: ...power supply is not needed The driver circuitry is protected in a NEMA enclosure suitable for indoor or outdoor mounting The anemometer is a 200 WS 01B Wind Speed sensor that includes 40 of cable and...

Страница 5: ...200 WS 23S KM 4 20 mA 0 200 kph Loop supply voltage range Connection Operating temperature range NEMA enclosure dimensions Cable to user equipment Measurement range Speed Constant Transducer type Spe...

Страница 6: ...Tighten the gland nut 3 Make sure there is a drip loop below the transmitter enclosure so that any moisture on the cable will not seep into the enclosure This is particularly important since the seal...

Страница 7: ...n of the monitoring equipment Disconnect the 200 WS 23 or 200 WS 23S from the device before doing these tests 1 Use a 4 20 mA signal generator to feed 6 mA into the selected channel on your monitoring...

Страница 8: ...2 3 4 GND WS REF REF EXC WD IMPORTANT CONNECT EARTH GROUND 200 WS 02F GREEN RED BLACK WHITE SHIELD BROWN 8 30 Vdc Wind Direction Signal 8 30 Vdc Wind Speed Signal 4 20 mA Input 8 30 Vdc 1 Signal Out...

Страница 9: ...ogger Power WIRING DIAGRAM 200 WS 23S JDC 9 03 2020 860 0029 01 1 2 3 4 GND WS REF REF EXC WD IMPORTANT CONNECT EARTH GROUND 200 WS 01B RED SHIELD BLACK 8 30 Vdc Wind Speed Signal 4 20 mA Input 8 30 V...

Отзывы: