43
6.3.4 When measuring VOR
If you select the VOR (see. 6.2), by pressing the
Measure
button below the screen, the VOR measure menu is
accessed. The submenus at the right side of the screen are:
1
[ FMI/Bearing ]
Measure primary parameters FMI and bearing
2
[ Mod depth ]
Measure modulation depth for 30Hz and 9960Hz in addition to RF
Level.
3
[ Ident ]
Measure ident modulation and frequency
4
[ Meas. Freq ]
Measure frequencies (9960Hz, carrier offset from nominal value,
30Hz and 30Hz subcarrier)
5
6
7
[ Other meas. ]
Access the stored procedure measur
8
[ Continuous log ]
Start logging continuously