Power & Gas Reader 

Revision: 2.2 

 

 
- MANUFACTURER SPECIFIC for electricity firmware: 

Manufacturer: 

150 

Product: 

Product type: 

 
- MANUFACTURER SPECIFIC for gas firmware: 

Manufacturer: 

150 

Product: 

Product type: 

16

 

 

 

II. Functioning modes 

 

The Power Reader has two functioning modes: 

- Real-time mode 
- Normal mode 
 

In real-time mode, the Power Reader will keep the antenna always on. In normal mode, 

the Power Reader will go to sleep and wake up as instructed by the WAKE UP SET command. 
 

III. Command classes 

 

In  the  following  section each  command  class  is  described  in detail.  Make  sure to  read 

the  "Integrating  with  third  party  controllers"  part  of  the  document  after  going  through  the 
command classes. 
 
1. COMMAND_CLASS_BASIC 
 

Using  the  command  class  basic,  the  controlling  node  can  control  the  Power  Reader's 

LED.  A  basic  set  command  will trigger the  Power  Reader's  LED to  light up.  The  Power  Reader 
will respond to the BASIC SET command with a BASIC REPORT representing the LED status.  
 

The basic get command will return a BASIC REPORT with value 1. 

 
2. COMMAND_CLASS_BATTERY 
 

Using  this  command  class,  the  Power  Reader  can  be  queried  for  battery  level.  The 

battery level is reported according to the command class specification as a value between 0 and 
100. Value 255 for low battery is not supported. 
 
 
 

Содержание NQ-9021

Страница 1: ...NorthQ Power Gas Reader Revision 2 2 1 NorthQ Power and Gas Reader NQ 9021 Technical Integration Z Wave Commands Document revision 2 2 Date January 30 2015...

Страница 2: ...ranties or conditions whether expressed orally or implied in law including implied warranties and conditions of merchantability or fitness for a particular purpose NorthQ ApS specifically disclaims an...

Страница 3: ...ng has different firmware than the Power Reader for gas metering Please make sure you have the appropriate firmware on your device before you start integrating installing it The proper way of distingu...

Страница 4: ...is described in detail Make sure to read the Integrating with third party controllers part of the document after going through the command classes 1 COMMAND_CLASS_BASIC Using the command class basic t...

Страница 5: ...entire firmware file including headers Initial crc value is 0xFFFF 5 COMMAND_CLASS_TIME_PARAMETERS Use this command class to set the Power Reader s real time clock The command class is implemented ac...

Страница 6: ...ulse factor in imp Wh instead of imp kWh In this case the value must be converted to imp kWh before multiplying by 10 and writing this value in the register In order to convert imp Wh to imp kWh the v...

Страница 7: ...e for the Power Reader within 3 seconds then this register should be set to the number of seconds that it will take the controlling node to send a response request to the wake up notification Register...

Страница 8: ...irmware Manufacturer 150 Product 1 Product type 1 MANUFACTURER SPECIFIC for gas firmware Manufacturer 150 Product 1 Product type 16 10 COMMAND_CLASS_VERSION This command class is implemented according...

Страница 9: ...e wake up node 255 most probably has historical data in his storage You can pull that from the Power Reader as the user might want to see his historical consumption through your UI use the basic comm...

Страница 10: ...ess it is absolutely necessary as it will require the antenna to send more bytes than the regular command class By sending more bytes the battery lifetime is affected leave register 10 at 3 seconds If...

Страница 11: ...consumption on the meter and the meter disk spins very slow set the pulse count register with the proper value as described in COMMAND_CLASS_CONFIG show the user the real time consumption using comma...

Отзывы: