Control# 4007135
Conforms to UL 2523, Certified to CAN/CSA B366.1
Electrical Rating: 120 V, 60 HZ, 15 AMPS, 1
Φ
Certified As An Add On Model Date September 2012
INSTALLATION:
Use only chimney suitable for solid fuel. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING
ANOTHER APPLIANCE. Place only on non-combustible flooring with adequate support. Maintain the following minimum clearances to
combustibles: Sides – 8 Ft. (2.44 m), Front – 8 Ft. (2.44 m), Back – 8 Ft. (2.44 m)
CAUTION:
This equipment may only be installed by qualified personnel.
OPERATION:
Refer to owner’s manual supplied with this appliance. Burn Wood Only. Load fuel carefully.
DO NOT ALTER THE FUEL FEEDING EQUIPMENT IN ANY WAY.
Burn Wood Only
DANGER
– Risk of Fire Or Explosion: Do not use chemical fluids to start the fire. Do not burn garbage, gasoline, naphtha, engine oil, or the
other inappropriate materials. Do not store fuel within the above minimum clearances. Do not operate with fuel door, ash removal door, or
clean-out doors open. Turn off electrical power before servicing.
CAUTION
– Hot Surfaces: Keep children away. Do not touch during operation.
The heat exchanger, flue pipe, and chimney must be cleaned regularly to remove accumulated creosote and ash. Ensure that the heat exchanger
tubes, burn chamber and chimney are cleaned at the end of the heating season to minimize corrosion during the summer months. The appliance,
flue pipe, and chimney must be in good condition.
This unit may be connected to an existing boiler system. Follow instructions in owner’s manual.
OPERATE THE (OIL, GAS, ELECTRIC) BOILER PERIODICALLY TO ENSURE IT WILL OPERATE SATISFACTORILY WHEN
NEEDED.
DO NOT RELOCATE OR BYPASS ANY OF THE SAFETY CONTROLS IN THE ORIGINAL BOILER INSTALLATION.
CAUTION: THIS EQUIPMENT MAY ONLY BE INSTALLED BY QUALIFIED PERSONNEL.
DISCONNECT ELECTRIC POWER TO BOTH BOILERS BEFORE SERVICING.
CAUTION: MAINTAIN COMBUSTION AIR SUPPLY TO BOTH BOILERS. AIR STARVATION IS DANGEROUS.
PROVIDE A FRESH AIR OPENING AT LEAST 3 in
2
(2,000 mm
2
).
In the event of a power failure the system will resume normal function when power is restored. Depending on the duration of power outage the
furnace may need to be cleaned & the fire relit. This unit can also be run by a portable generator providing 120V, 60 Hz, 15 Amps. Unplug from
power source & plug into generator. Fans & circulating pumps will be operating normally; follow your normal refueling instructions to check
status of fire. Reconnect to normal power supply when power has resumed.
In the event of a chimney fire or “run-away fire” – be sure fans are off, circulating pumps are running, loading door, rear clean out doors are
closed tight, check dampers are closed tight, check water level is ok.
When fire is in control it is ok to operate stove in normal operating mode. Be sure to find the source of the run-away fire causes can be burning
fuel other than wood, doors left open, seals around door need replacing or damper stuck open. Correct any of these conditions.
For Outdoor Installation Only.
Manufactured by Northern Metalworks, 4 Thompson Road, PO Box 550, Sunderland, ON, L0C 1H0
Date of Manufacture: Month _____________________, Year______________________
UL and CSA
Certification