background image

 

 

Wave PERFORMANCE Monitors (PPCs) 

 

Specifications subject to changes without prior notice. The contents of 

this page are property of North Invent Norway AS. All rights herein are 

reserved to North lnvent Norway AS. This document cannot be 

reproduced without the written permission of the company. 

 

NORTH INVENT 
Sørhauggata 128, NO-5527 Haugesund, Norway  
Phone: + 47 48 84 02 00 
[email protected]  www.northinvent.com 

5

 

3.  Product Identification 

 
On the backside there are three markings identifying the Panel PC.  
 
Display Unit (DIU) P/N and serial number 
Electronics Unit (ELU) P/N and serial number 
Complete Panel PC P/N and service tag number 
 
Upon request we can assign an additional customer specific P/N.  
 
Please see separate document for details about product numbering.  
 
 

4.  Packaging and Delivery 

 
Please check the delivered goods immediately on receipt with respect to damages caused by transportation and inform the 
delivering freight carrier immediately, on site, about any visible transport damages. Additionally, inform us immediately in 
writing, at the latest within 5 workdays, about any visible transport damages. At reception, the delivery includes the 
following items: 
 
Wave PERFORMANCE Monitor (Panel PC) 
AC power cable 
DC power plug (optional) 
DP cable (optional)  
 

 

5.  Mechanical Dimensions 

 

For panel cut out drawings and mechanical dimensions of Panel PCs see data sheets. 
 
 

6.  Compass Safe-distance: 

 
Every panel PC is tested in order to determine the minimum safe distances at which it should be installed from both the 
steering and the standard magnetic compasses, so not to significantly affect the accuracy of these compasses. A safe 
distance takes into account both the constant effect on a magnetic compass by the presence of magnetic material, but also 
any variable effect due e.g., electrical circuits or the opening/closing of drawers or panels. Thus, provided that a Panel PC 
is not placed in a position nearer to the center of the magnetic compass than the recommended safe distance, the Panel PC 
may be installed or removed without any need for adjustment of that compass.

 

 

The safe compass distances are mentioned on every Panel PC and/or in the corresponding datasheet. 
 

 

Содержание Wave PERFORMANCE

Страница 1: ...rth lnvent Norway AS This document cannot be reproduced without the written permission of the company Wave PERFORMANCE Monitors PPCs NORTH INVENT S rhauggata 128 NO 5527 Haugesund Norway Phone 47 48 8...

Страница 2: ...47 48 84 02 00 post northinvent com www northinvent com 2 Table of Contents 1 Terms and Abbreviations 3 2 Panel PC Description 4 3 Product Identification 5 4 Packaging and Delivery 5 5 Mechanical Dime...

Страница 3: ...efore starting to operate the Panel PC we would like to suggest that you carefully read through the present document as our aim with this User s Manuel is to give you the best experience in using your...

Страница 4: ...while eliminating corrosion problems The electronics include a specifically designed Power Supply a high quality Display Controller a Backlight LED driver and a custom made Interface Board The Panel P...

Страница 5: ...t damages Additionally inform us immediately in writing at the latest within 5 workdays about any visible transport damages At reception the delivery includes the following items Wave PERFORMANCE Moni...

Страница 6: ...Plate for a Panel PC with AC DC power input and four serial ports Optionally two serial ports can be replaced with two additional Ethernet ports 7 1 Pin Assignments AC Power Pin Description Pin Descri...

Страница 7: ...ML_LN0P Lane 0 19 POR Return for Power 6 ML_L2P Lane 2 13 Config1 connected to GND 20 PO Power 3 3V 500mA 7 ML_L1N Lane 1 14 Config2 connected to GND RS232 DB9 Plug Pin Description Pin Description Pi...

Страница 8: ...45 Pin Description Pin Description 1 DA 5 DC 2 DA 6 DB 3 DB 7 DD 4 DC 8 DD USB A Pin Description Pin Description 1 GND 3 Data 2 Data 4 Vcc HMI DSUB 15 Pin Description Pin Description Pin Description 1...

Страница 9: ...his page are property of North Invent Norway AS All rights herein are reserved to North lnvent Norway AS This document cannot be reproduced without the written permission of the company NORTH INVENT S...

Страница 10: ...of calibration files will be provided to allow the operating system to apply the calibration when it is installed The calibration files may be obtained from a USB pen drive enclosed with the Panel PC...

Страница 11: ...ssible to control the Panel PC backlight brightness and buzzer via Ethernet using SNMP An SNMP agent must be installed using the following procedure Microsoft Net Core 3 1 is required to run the North...

Страница 12: ...to North lnvent Norway AS This document cannot be reproduced without the written permission of the company NORTH INVENT S rhauggata 128 NO 5527 Haugesund Norway Phone 47 48 84 02 00 post northinvent c...

Страница 13: ...owing examples presumes that NetSNMP is installed in the local machine Control Command Get backlight value snmpget v2c cpublic localhost 1 3 6 1 4 1 30329 1 1 3 2 0 Set backlight 55 snmpset v2c cpubli...

Страница 14: ...he brightness is set to 100 using the backlight UP key HMI connected Picture is too dark Increase the brightness using the backlight UP key HMI connected Increase the brightness using the Windows Disp...

Отзывы: