Equipment replacement Page 33 of 34
QCA144 1.5 MB/S RPE Cabinet
Maintenance and equipment replacement
Procedure 17
Peripheral Equipment Shelf Backplane replacement
1
Log in to the system and load overlay program 32 as described in
553-2301-511.
2
Disable the PE shelf being replaced using command DISS 1 s, where
1 is the loop number and s is the shelf number.
Note: If the loop is extended to a second PE shelf, that shelf must also
be disabled.
3
If the backplane being replaced is located on the same level as the
RPE shelf in the first tier (base) of the cabinet, remove the PE1 fuse
from the QUX19 power unit.
If the backplane being replaced is located in shelf positions 2 through
5, set the corresponding PE breaker (PE2, PE3, PE4, or PE5).
4
If the backplane being replaced is in positions 2 through 5 and the
cabinet is equipped with EMI shields, tag and disconnect cables from
connectors A, B, C, D, E, and F on the back of the shelf next to the
backplane being replaced.
5
If the cabinet is equipped with EMI shields, remove the screws
securing the shield behind the backplane being replaced.
6
Disconnect power cable from connector J on the backplane being
replaced.
7
Unseat all circuit packs from backplane being replaced.
8
Remove the hex screws securing the top and bottom of the backplane
to the cabinet and remove backplane.
9
Position the new backplane and secure to cabinet with hex screws.
10
Reconnect power cable to connector J on backplane.